88 / 113 page ![]() ADP1052 Data Sheet Rev. B | Page 88 of 113 Bits Bit Name/Function R/W Description [3:0] CS2 light load threshold R/W These bits set the current limit on the CS2 ADC to enter the light load mode value. This value determines the point at which the LIGHT_LOAD flag is set. The hysteresis and the averaging speed are programmable in Register 0xFE1E[5:2]. Bit 3 Bit 2 Bit 1 Bit 0 Light Load Threshold (mV) 328 μs 164 μs 82 μs 41 μs 0 0 0 0 0 0 0 0 0 0 0 1 0.9375 1.8750 3.7500 7.5000 0 0 1 0 1.8750 3.7500 7.5000 15.000 0 0 1 1 2.8125 5.6250 11.250 22.500 0 1 0 0 3.7500 7.5000 15.000 30.000 0 1 0 1 4.6875 9.3750 18.750 37.500 0 1 1 0 5.6250 11.250 22.500 45.000 0 1 1 1 6.5625 13.125 26.250 52.500 1 0 0 0 7.5000 15.000 30.000 60.000 1 0 0 1 8.4375 16.875 33.750 67.500 1 0 1 0 9.3750 18.750 37.500 75.000 1 0 1 1 10.313 20.625 41.250 82.500 1 1 0 0 11.250 22.500 45.000 90.000 1 1 0 1 12.188 24.375 48.750 97.500 1 1 1 0 13.125 26.250 52.500 105.00 1 1 1 1 14.063 28.125 56.250 112.50 Table 131. Register 0xFE1A—IIN_OC_FAST_FAULT_LIMIT and SR_RC_FAULT_LIMIT Bits Bit Name/Function R/W Description 7 Reserved R/W Reserved. [6:4] IIN_OC_FAST_ FAULT_LIMIT R/W If the CS1 cycle-by-cycle current-limit comparator is set and the CS1_OCP flag is triggered, all PWM outputs that are on at that time can be programmed to be immediately disabled for the remainder of the switching cycle. The PWM outputs resume normal operation at the beginning of the next switching cycle. There is an internal counter, N, with an initial value of 0. N counts the CS1_OCP flag triggering number in consecutive switching cycles. If the CS1_OCP flag is triggered in one cycle, then NCURRENT = NPREVIOUS + 2. If the CS1_OCP flag is not triggered in one cycle and the previous N > 0, then NCURRENT = NPREVIOUS − 1. If the CS1_OCP flag is not triggered and the previous N = 0, then NCURRENT = 0. When N reaches the IIN_OC_FAST_FAULT_LIMIT value, the IIN_OC_FAST_FAULT flag is set. Note that there is one cycle in single-ended topologies, such as buck converter and forward converter. There are two cycles in double-ended topologies, such as full bridge converter, half bridge converter, and push pull converter. Bit 6 Bit 5 Bit 4 Limit Value 0 0 0 2 0 0 1 8 0 1 0 16 0 1 1 64 1 0 0 128 1 0 1 256 1 1 0 512 1 1 1 1024 3 SR_RC_FAULT flag debounce time R/W This bit sets the debounce time for the SR_RC_FAULT flag. 0 = 40 ns. 1 = 200 ns. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |