34 / 113 page ![]() ADP1052 Data Sheet Rev. B | Page 34 of 113 DUTY CYCLE READING The READ_DUTY_CYCLE command (Register 0x94, which gives the duty cycle of the PWM output value) is updated every 10 ms. Register 0xFE58[5:2] is set for correct reading of general PWM type topologies; these bits select the PWM channel (OUTA to OUTD) for which the duty cycle value is reported. When phase- shifted full bridge topology is used, Register 0xFE58[1] must be set to 1. The duty cycle value is calculated based on the overlapping of the timing of OUTA and OUTD. SWITCHING FREQUENCY READING The READ_FREQUENCY command (Register 0x95) is used to report the switching frequency information in kHz. TEMPERATURE READING The RTD pin (Pin 23) is set up for use with an external negative temperature coefficient (NTC) thermistor. The RTD pin has an internal programmable current source. An ADC monitors the voltage on the RTD pin. The RTD ADC has an input range of 1.6 V. The raw data is stored in Register 0xFEAB. It is a 12-bit reading, which means that the LSB size is 1.6 V/4096 = 390.625 μV. Using Register 0xFE2D[7:6], an internal precision current source can be configured to generate a 10 μA, 20 μA, 30 μA, or 40 μA current. This current source can be trimmed by means of an internal DAC to compensate for thermistor accuracy. To set the current source to the factory default value of 46 μA, write 0xE6 to Register 0xFE2D. The output of the RTD ADC is linearly proportional to the voltage on the RTD pin; however, thermistors exhibit a nonlinear function of resistance vs. temperature. Therefore, it is necessary to perform postprocessing on the RTD ADC reading to read the temperature accurately. By connecting an external resistor in parallel with the NTC ther- mistor, linearization is achieved. Figure 36 shows the RTD and OTP operation. Using the factory default value of 46 μA and the linearization scheme, the temperature, expressed in degrees Celsius (°C), can be read directly via the READ_TEMPERATURE command (Register 0x8D). The temperature reading is derived from the RTD ADC output at an update rate of every 10 ms; however, by using Register 0xFE65[2:0], the update rate can be changed to 63 ms, 126 ms, 252 ms, or 504 ms. The ADP1052 implements a linearization scheme based on a preselected combi- nation of external components and current selection (see the Temperature Linearization Scheme section). Optionally, the user can process the RTD reading and perform postprocessing in the form of a lookup table or polynomial equation to match the specific NTC thermistor used. In this case, the external resistor in parallel is not needed. With an internal current source of 46 μA, the equation to calculate the ADC code at a certain NTC value (RX) is given by the following formula: ADC CODE = 46 μA × Rx/390.7 μV For example, at 60°C, the NTC thermistor connected to the RTD pin is 21.82 kΩ. Therefore, RTD ADC CODE = 46 μA × 21.82 kΩ/390.7 μV = 2570 For the overtemperature function, the RTD threshold (in volts) can be transferred through the OT_FAULT_LIMIT command in Register 0x4F, using the linearization equations shown in the Temperature Linearization Scheme section. Alternatively, the temperature reading and overtemperature protection function can be implemented by applying an external analog temperature sensor, such as the STLM20. See Figure 35 for more information. Using this solution, the temperature sense range can be as low as −40°C. To facilitate this approach, disable the internal current by writing 0x00 to Register 0xFE2D and setting Register 0xFE2B[2]. The temperature reading in °C can be derived by the following formula: T = 159.65 − R2 R2 R1 CODE ADC + × 92 . 29 where the ADC CODE is the reading in Register 0xFEAB[15:4]. The recommended values of R1 and R2 are 20 kΩ and 10 kΩ, respectively. RTD RTD ADC RTD TEMPERATURE VALUE REGISTER R2 10kΩ 10µA/20µA/30µA/40µA REG 0xFEAB[15:4] R1 20kΩ STLM20 VOUT GND Figure 35. Temperature Sensing by an Analog Temperature Sensor RTD RTD ADC 100kΩ NTC OT_FAULT_LIMIT REG 0x4F RTD TEMPERATURE VALUE REGISTER OT_FAULT RESPONSE 16.5kΩ 10µA/20µA/30µA/40µA REG 0xFEAB[15:4] SIGNAL CONDITIONING TEMPERATURE VALUE IN CELSIUS READ_TEMPERATURE REG 0x8D OT_FAULT FLAG REG 0x7D[7] PGOOD OT_FAULT_RESPONSE REG 0x50 Figure 36. RTD and OTP Operation |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |