| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ADP1052ACPZ-R7 Folha de dados(PDF) 38 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1052ACPZ-R7 Folha de dados(HTML) 38 Page - Analog Devices |
|
38 / 113 page ![]() ADP1052 Data Sheet Rev. B | Page 38 of 113 CS1 CYCLE-BY-CYCLE CURRENT LIMIT THRESHOLD OUTA CS1 PIN SIGNAL COMPARATOR OUTPUT CS1_OCP FLAG t0 tBLANKING tBLANKING tDEBOUNCING tDEBOUNCING tS Figure 40. CS1 Cycle-by-Cycle Current-Limit Timing When the CS1_OCP flag triggers, Register 0xFE08[6:5] and Register 0xFE0E[7:4] can be used to disable all PWM outputs for the remainder of the switching cycle; they are reenabled at the start of the next switching cycle. During one switching cycle, if the rising edge of a PWM output occurs after the CS1_OCP flag is triggered, the PWM remains enabled for the switching cycle. To avoid current overstress of the body diode of the synchronous rectifiers, the cycle-by-cycle current-limit actions of the SR1 and SR2 outputs can be further programmed by Register 0xFE1E[1:0]. Program the SRx outputs in the same way as the other PWM outputs, or program them so that when the CS1_OCP flag triggers, the SR PWM output turns on. There is a 145 ns to 180 ns delay (dead time) between the CS1_OCP flag being triggered and the turning on of the SR PWM outputs. The falling edges continue to follow the programmed value. The cycle-by-cycle current limit is always activated regardless of the IIN overcurrent fast protection settings. The comparator output can be completely ignored by setting Register 0xFE1F[7]. IIN Overcurrent Fast Protection There is an internal counter, N. N is a positive integer or zero, with an initial value of 0. The counters work as follows: When the CS1_OCP flag is triggered in one cycle (the CS1 OCP comparator is triggered high), N is counted as NCURRENT = NPREVIOUS + 2 If the CS1_OCP flag is not triggered in one cycle and NPREVIOUS is greater than 0, then NCURRENT = NPREVIOUS − 1 If the CS1_OCP flag is not triggered in one cycle and NPREVIOUS equals 0, then NCURRENT = 0 When the value of N reaches the limit specified by IIN_OC_ FAST_FAULT_LIMIT, the IIN_OC_FAST_FAULT flag is triggered (see Figure 41). CS1 CYCLE-BY-CYCLE CURRENT LIMIT REFERENCE CS1 SIGNAL COMPARATOR OUTPUT IIN_OC_FAST_FAULT FLAG REG 0xFEA0[5] IIN_OC_FAST_FAULT FLAG REG 0x7C[2] IIN_OC_FAST_FAULT FLAG REG 0xFEA[5] t0 tS 2 tS 3 tS 4 tS 5 tS 6 tS 7 tS Figure 41. IIN Overcurrent Fast Fault Triggering For the single-ended topologies, such as forward converter and buck converter, a switching cycle consists of one cycle. For the double-ended topologies, such as full bridge converter, half bridge converter, and push pull converter, there are two cycles in a switching cycle. The IIN_OC_FAST_FAULT_LIMIT bits are in Register 0xFE1A[6:4]. In Figure 41, the IIN_OC_FAST_ FAULT_LIMIT value is set to 8. The response of the IIN_OC_FAST_FAULT flag can be programmed in the IIN_OC_FAST_FAULT_RESPONSE bits (Register 0xFE00[3:0]). See the Manufacturer Specific Protection Responses section and the register settings for the action details. Matched Cycle-by-Cycle Current Limit in a Half Bridge Converter For the half bridge converter, the cycle-by-cycle current-limit feature, described previously, cannot guarantee the balance of duty cycles between two half cycles in one switching cycle. The imbalances of each half cycle can cause the center point voltage of the capacitive divider to drift from VIN/2 toward either the ground or the input voltage, VIN. This drift, in turn, can lead to output voltage regulation failure, transformer saturation, and doubling of the drain to source voltage (VDS) stress of the synchronous rectifiers. To compensate for these imbalances, matched cycle-by-cycle current limiting is implemented in the ADP1052 by forcing each cycle to be equalized, or matched, to the previous one. When the matched cycle-by-cycle current limit is triggered, the duty cycle in the following half cycle exactly matches the actual duty cycle in the preceding half cycle. However, the cycle-by-cycle current limit is always the highest priority to terminate the PWM channels. For example, if one previous cycle has a duty cycle of 20% under a cycle-by-cycle current-limit condition, the following cycle should also be matched to a duty cycle of 20%. However, if the cycle-by-cycle current limit occurs in the following cycle and it must terminate the PWM with a smaller duty cycle, the cycle- by-cycle current limit takes higher priority and the duty cycle can be a value that is smaller than 20%. The matched cycle-by-cycle current limit is enabled by Regis- ter 0xFE1D[6]. Register 0xFE1D[5:4] sets the PWM pairs for the matched cycle-by-cycle current limit. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |