| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ADP1052ACPZ-R7 Folha de dados(PDF) 71 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1052ACPZ-R7 Folha de dados(HTML) 71 Page - Analog Devices |
|
71 / 113 page ![]() Data Sheet ADP1052 Rev. B | Page 71 of 113 POWER_GOOD_ON The POWER_GOOD_ON command sets the output voltage (in volts) at which the POWER_GOOD signal asserts. The POWER_GOOD status bit (POWER_GOOD) in the STATUS_WORD command is always reflective of VOUT with regard to the POWER_GOOD_ON and POWER_GOOD_OFF limits. Table 48. Register 0x5E—POWER_GOOD_ON Bits Bit Name/Function R/W Description [15:0] Mantissa R/W Sets the output voltage for the POWER_GOOD_ON command. 16-bit, unsigned Integer Y value for linear format X = Y × 2N. N is defined by the VOUT_MODE command. POWER_GOOD_OFF The POWER_GOOD_OFF command sets the output voltage (in volts) at which the POWER_GOOD signal is negated. The POWER_GOOD status bit (POWER_GOOD) in the STATUS_WORD command is always reflective of VOUT with regard to the POWER_GOOD_ON and POWER_GOOD_OFF limits. Table 49. Register 0x5F—POWER_GOOD_OFF Bits Bit Name/Function R/W Description [15:0] Mantissa R/W Sets the output voltage for the POWER_GOOD_OFF command. 16-bit, unsigned Integer Y value for linear format X = Y × 2N. N is defined by the VOUT_MODE command. TON_DELAY The TON_DELAY command sets the turn-on delay time in milliseconds (ms).The ADP1052 supports only those options listed in Table 50. Table 50. Register 0x60—TON_DELAY (Turn-On Delay Options Supported in the ADP1052) Register Setting Turn-On Delay Time (ms) 0000000000000000 (0x0000) 0 0000000000001010 (0x000A) 10 0000000000011001 (0x0019) 25 0000000000110010 (0x0032) 50 0000000001001011 (0x004B) 75 0000000001100100 (0x0064) 100 0000000011111010 (0x00FA) 250 0000001111101000 (0x03E8) 1000 Table 51. Register 0x60—TON_DELAY Bits Bit Name/Function R/W Description [15:11] Exponent R/W 5-bit, twos complement, N value for linear format, X = Y × 2N. [10:0] Mantissa R/W 11-bit, twos complement, Y value for linear format, X = Y × 2N. TON_RISE The TON_RISE command sets the turn-on rise time in ms. Only the values listed in Table 52 are supported in the ADP1052. Table 52. Register 0x61—TON_RISE (Turn-On Rise Time Options Supported in the ADP1052) Register Setting Turn-On Rise Time (ms) 1100000000001101 (0xC00D) 0.05 1101000000001101 (0xD00D) 0.2 1111000000000111 (0xF007) 1.75 1111100000010101 (0xF815) 10.5 0000000000010101 (0x0015) 21 1111000010100001 (0xF0A1) 40.25 0000000000111100 (0x003C) 60 0000000001100100 (0x0064) 100 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |