Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

ADP1053ACPZ-R7 Folha de dados(PDF) 46 Page - Analog Devices

Nome de Peças ADP1053ACPZ-R7
Descrição Electrónicos  3-Channel Digital
PDF  84 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  AD [Analog Devices]
Página de início  http://www.analog.com
Logo AD - Analog Devices

ADP1053ACPZ-R7 Folha de dados(HTML) 46 Page - Analog Devices

Back Button ADP1053ACPZ-R7 Datasheet HTML 42Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 43Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 44Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 45Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 46Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 47Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 48Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 49Page - Analog Devices ADP1053ACPZ-R7 Datasheet HTML 50Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 46 / 84 page
background image
ADP1053
Data Sheet
Rev. A | Page 46 of 84
PMBus COMMAND DESCRIPTIONS
CLEAR_FAULTS COMMAND
Command 0x03, send byte, no data. This command clears all fault bits in the STATUS_WORD register.
WRITE_PROTECT COMMAND
Table 14. Command 0x10—WRITE_PROTECT
Bits
Bit Name
R/W
Description
7
Write Protect 1
R/W
Setting this bit disables writes to all commands except for WRITE_PROTECT.
6
Write Protect 2
R/W
Setting this bit disables writes to all commands except for WRITE_PROTECT, OPERATION, and PAGE.
5
Write Protect 3
R/W
Setting this bit disables writes to all commands except for WRITE_PROTECT, OPERATION, PAGE,
ON_OFF_CONFIG, and VOUT_COMMAND.
[4:0]
Reserved
R
Reserved.
RESTORE_DEFAULT_ALL COMMAND
Command 0x12, send byte, no data. This command downloads the factory default settings from EEPROM (Page 0) into operating memory.
STORE_USER_ALL COMMAND
Command 0x15, send byte, no data. This command copies the entire contents of operating memory into EEPROM (Page 1 of the main block).
The EEPROM must first be unlocked.
RESTORE_USER_ALL COMMAND
Command 0x16, send byte, no data. This command downloads the stored user settings from EEPROM (Page 1 of the main block) into
operating memory.
CAPABILITY COMMAND
This command allows host systems to determine the capabilities of the PMBus device.
Table 15. Command 0x19—CAPABILITY (Default Value = 0x20)
Bits
Bit Name
R/W
Description
7
Packet error
checking
R
Always reads 0. Packet error checking (PEC) is not supported.
[6:5]
Maximum bus
speed
R
Return the device PMBus speed capability. Always reads 01 (maximum bus speed is 400 kHz).
4
SMBALERT#
R
Always reads 0. SMBALERT# pin and SMBus alert response protocol are not supported.
[3:0]
Reserved
R
Reserved.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com