20 / 140 page ![]() ADP1055 Data Sheet Rev. A | Page 20 of 140 incorporates this phase delay into its calculations. Note that the GUI does not account for other delays such as gate driver and propagation delays. DIGITAL FILTER PROGRAMMING REGISTERS Three sets of registers allow three different filters to be programmed. Normal mode filter (used for CCM or heavy load and configured in Register 0xFE01 to Register 0xFE04) Light load mode filter (configured in Register 0xFE05 to Register 0xFE08) Soft start filter (configured in Register 0xFE09 to Register 0xFE0C) The software GUI allows the user to program the light load mode filter in the same manner as the normal mode filter. It is recommended that the GUI be used for this purpose. DIGITAL COMPENSATION FILTERS DURING SOFT START The ADP1055 has a dedicated soft start filter (SSF) that can be used to fine-tune and optimize the dynamic response during the output voltage ramp-up. During soft start, the ADP1055 determines the load condition and after the voltage reaches 12.5% of the nominal output voltage value, it determines the current load condition and switches filters accordingly to the light load mode threshold (Register 0xFE5F[3:1]). If the load current is below the light load mode threshold, the ADP1055 switches to the light load mode filter (LLF). If the load current is above the light load mode threshold, the normal mode filter is used until the end of the soft start ramp, even if the device subsequently enters light load mode based on a change to the load current. Other configurations can be programmed to use different filters during soft start, as follows: Force soft start filter (Register 0xFE51[2]). This option forces the ADP1055 to use the soft start filter. In some cases, this option allows better fine-tuning of the ramp-up voltage. Disable light load mode during soft start (Register 0xFE51[1]). This option prevents the use of the light load mode filter during soft start, even if the light load condition is met. The light load mode filter is available for use after the end of the soft start ramp. Figure 23 shows the use of filters during soft start. Figure 23. Digital Filters During Soft Start (Low Temperature Filter Not Shown) As shown in Figure 23, in Zone 1, the ADP1055 starts with the normal mode filter or the soft start filter. Zone 2 begins when the voltage reaches 12.5% of the nominal output voltage value. At this point, the ADP1055 checks whether the system is in light load mode, and the choice of filter is based on the following criteria: If the system is in light load mode, the ADP1055 switches to the light load mode filter (unless the option to disable the LLM filter was previously selected). If the system is not in light load mode, the ADP1055 continues to use the filter used in Zone 1: the normal mode filter or the soft start filter. The ADP1055 changes to the LLM filter if the load changes during Zone 2 (voltage rises from 12.5% to 100% of the soft start ramp. The filter does not revert to LLM if the load drops until after the end of soft start. In Zone 3 the filter changes to the NMF or LLM filter, depending on the load. FILTER TRANSITION To avoid output voltage glitches and to provide a seamless transition from one filter to another, the ADP1055 supports programmable filter transitions. This feature allows a gradual transition from one filter to another. Filter transitions are programmed using Register 0xFE4A[2:0]. When the ADP1055 switches filters, the switching action is changed in 32 steps. The step size can be programmed over several cycles (1tSW to 32tSW) to avoid glitches in the output. The filter used depends on the state of the synchronous rectifiers and whether the system is in continuous conduction mode (CCM) or discontinuous conduction mode (DCM) (see Table 5). Table 5. State of Synchronous Rectifiers and Filter Used State of SRx Outputs Load Regular Mode Diode Emulation Mode Filter Used Medium to heavy load SRs in CCM SRs in CCM Normal mode filter (Register 0xFE01 to Register 0xFE04). Below LLM threshold SRs in LLM Diode emulation SRs LLM filter (Register 0xFE05 to Register 0xFE08.) When diode emulation mode is in use, the LLM filter is activated after the LLM threshold is crossed. Deep LLM SRs are off SRs are off LLM filter (Register 0xFE05 to Register 0xFE08). PS ON 12.5% REF NMF/SSF ZONE 1 LLF NMF/SSF LLM/NMF BASED ON LOAD LLM/NMF BASED ON LOAD NMF/SSF RAMP TIME 0x5F VOUT ZONE 3 ZONE 2 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |