| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ADP1055ACPZ-R7 Folha de dados(PDF) 75 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1055ACPZ-R7 Folha de dados(HTML) 75 Page - Analog Devices |
|
75 / 140 page ![]() Data Sheet ADP1055 Rev. A | Page 75 of 140 Bits Bit Name R/W Description [5:3] Retry setting R/W Number of retry attempts following a fault condition. A fault condition can be cleared by a reset, a power-off/power-on sequence, or a loss of bias power. Bit 5 Bit 4 Bit 3 Number of Retries 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 Infinite [2:0] Delay times R/W Number of delay time units (see Register 0xFE3E). TOFF_DELAY The TOFF_DELAY command sets the turn-off delay time in milliseconds (ms) from stop (ON_OFF_CONFIG) until the device stops transferring energy to the output. The range is 0 ms to 1023 ms, in steps of 1 ms. The calculated value is rounded down. Table 66. Register 0x64—TOFF_DELAY Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). TOFF_FALL The TOFF_FALL command sets the fall time (in ms) from the end of the turn-off delay time to voltage = 0 V. Table 67. Register 0x65—TOFF_FALL Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). TOFF_MAX_WARN_LIMIT The TOFF_MAX_WARN_LIMIT command sets the upper time threshold (in ms) that causes a TOFF_MAX warning condition, that is, the time it takes to power down the output voltage from VOUT to 12.5% of VOUT. The device notifies the host and sets the NONE_OF_THE_ ABOVE bit in the STATUS_BYTE register, the VOUT bit in the STATUS_WORD register, and the TOFF_MAX_WARNING bit in the STATUS_VOUT register. Table 68. Register 0x66—TOFF_MAX_WARN_LIMIT Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). POUT_OP_FAULT_LIMIT The POUT_OP_FAULT_LIMIT command sets the upper power threshold (in watts) measured at the sense/output pin that causes an output overpower fault condition. Table 69. Register 0x68—POUT_OP_FAULT_LIMIT Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |