| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ADP1055ACPZ-R7 Folha de dados(PDF) 77 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1055ACPZ-R7 Folha de dados(HTML) 77 Page - Analog Devices |
|
77 / 140 page ![]() Data Sheet ADP1055 Rev. A | Page 77 of 140 STATUS_WORD The STATUS_WORD register returns the upper and lower bytes of the STATUS_WORD command. A value of 1 in this command indicates that a fault has occurred. Table 72. Register 0x79—STATUS_WORD Bits Bit Name R/W Description 15 VOUT R Output voltage fault or warning. A bit in STATUS_VOUT is set. 14 IOUT/POUT R Output current or output power fault or warning. A bit in STATUS_IOUT is set. 13 INPUT R Input voltage, input current, or input power fault or warning. A bit in STATUS_INPUT is set. 12 MFR R Manufacturer-specific fault or warning. 11 POWER_GOOD R POWER_GOOD is a negation of POWER_GOOD, which means that the output power is not good. This bit is set when the sensed VOUT is less than the limit programmed in the POWER_GOOD_OFF command. 10 FANS R Not supported. 9 OTHER R A bit in STATUS_OTHER is set. 8 UNKNOWN R A fault or warning not listed in STATUS_WORD[15:1]. 7 BUSY R/W This bit is asserted if the device is busy and unable to respond. 6 POWER_OFF R This bit is asserted if the unit is not providing power to the output. 5 VOUT_OV_FAULT R An output overvoltage fault has occurred. 4 IOUT_OC_FAULT R An output overcurrent fault has occurred. 3 VIN_UV_FAULT R An input undervoltage fault has occurred. 2 TEMPERATURE R A temperature fault or warning has occurred. 1 CML R A communications, memory, or logic fault has occurred. 0 NONE_OF_THE_ABOVE R A fault or warning not listed in Bits[7:1] has occurred. STATUS_VOUT The STATUS_VOUT register returns the status of the output voltage. A value of 1 in this command indicates that a fault has occurred. Table 73. Register 0x7A—STATUS_VOUT Bits Bit Name R/W Description 7 VOUT_OV_FAULT R/W An output overvoltage fault has occurred. 6 VOUT_OV_WARN R/W An output overvoltage warning has occurred. 5 VOUT_UV_WARN R/W An output undervoltage warning has occurred. 4 VOUT_UV_FAULT R/W An output undervoltage fault has occurred. 3 VOUT_MAX_WARN R/W An attempt was made to set the output voltage to a value greater than the VOUT_MAX command. 2 TON_MAX_FAULT R/W The device took too long to power up without reaching the VOUT_UV fault limit. 1 TOFF_MAX_WARN R/W The device took too long to power down to 12.5% of its output voltage. 0 VOUT_TRACKING_ERR R Not supported. STATUS_IOUT The STATUS_IOUT register returns the status of the output current. A value of 1 in this command indicates that a fault has occurred. Table 74. Register 0x7B—STATUS_IOUT Bits Bit Name R/W Description 7 IOUT_OC_FAULT R/W An output overcurrent fault has occurred. 6 IOUT_OC_LV_FAULT R/W An output overcurrent fault and a low voltage fault have occurred. 5 IOUT_OC_WARN R/W An output overcurrent warning has occurred. 4 IOUT_UC_FAULT R/W An output undercurrent fault has occurred. 3 ISHARE_FAULT R/W A current sharing fault has occurred. 2 PLIM_MODE R Not supported. 1 POUT_OP_FAULT R/W An output overpower fault has occurred. 0 POUT_OP_WARN R Not supported. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |