66 / 140 page ![]() ADP1055 Data Sheet Rev. A | Page 66 of 140 IOUT_CAL_OFFSET The IOUT_CAL_OFFSET command is used to null any offsets in the output current sensing circuit (in amperes). Table 37. Register 0x39—IOUT_CAL_OFFSET Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). VOUT_OV_FAULT_LIMIT The VOUT_OV_FAULT_LIMIT command sets the upper voltage threshold (in volts) measured at the sense/output pin that causes an overvoltage fault condition. The exponent N is set using VOUT_MODE[4:0]. Table 38. Register 0x40—VOUT_OV_FAULT_LIMIT Bits Bit Name R/W Description [15:0] Mantissa-Y R/W Unsigned Y-mantissa used in output voltage related commands in linear data format (V = Y × 2N). VOUT_OV_FAULT_RESPONSE The VOUT_OV_FAULT_RESPONSE command instructs the device on the actions to take due to an output overvoltage fault. The device notifies the host and sets the VOUT_OV_FAULT bit in the STATUS_BYTE register, the VOUT bit in the STATUS_WORD register, and the VOUT_OV_FAULT bit in the STATUS_VOUT register. Table 39. Register 0x41—VOUT_OV_FAULT_RESPONSE Bits Bit Name R/W Description [7:6] Response R/W Determines the device response to an overvoltage fault condition. Bit 7 Bit 6 Response 0 0 Do nothing. 0 1 Continue operation for the delay time (Bits[2:0]). If the fault persists, retry the number of times specified by Bits[5:3]. 1 0 Shut down, disable the output, and respond as programmed in the retry setting (Bits[5:3]). 1 1 Disable the output while the fault is present. Operation resumes and the output is enabled when the fault condition no longer exists. [5:3] Retry setting R/W Number of retry attempts following a fault condition. A fault condition can be cleared by a reset, a power-off/power-on sequence, or a loss of bias power. Bit 5 Bit 4 Bit 3 Number of Retries 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 Infinite [2:0] Delay time R/W Number of delay time units (see Register 0xFE3E). VOUT_OV_WARN_LIMIT The VOUT_OV_WARN_LIMIT command sets the upper voltage threshold (in volts) measured at the sense/output pin that causes an overvoltage warning condition. The exponent N is set using VOUT_MODE[4:0]. The device notifies the host and sets the NONE_OF_THE_ ABOVE bit in the STATUS_BYTE register, the VOUT bit in the STATUS_WORD register, and the VOUT_OV_WARNING bit in the STATUS_VOUT register. Table 40. Register 0x42—VOUT_OV_WARN_LIMIT Bits Bit Name R/W Description [15:0] Mantissa-Y R/W Unsigned Y-mantissa used in output voltage related commands in linear data format (V = Y × 2N). |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |