Back Button UCD3138064ARGCR.A Datasheet HTML 52Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 53Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 54Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 55Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 56Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 57Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 58Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 59Page - Texas Instruments UCD3138064ARGCR.A Datasheet HTML 60Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 56 / 84 page
background image
Start of Period
Period Counter
Start of Period
Period
Adaptive Sample Trigger B
Sample Trigger 1
DPWM Output A
Cycle Adjust A (High Resolution)
Filter Duty (High Resolution)
Event 1
Event 2 - Event 3 (High Resolution)
Event 4 (High Resolution)
DPWM Output B
Blanking A Begin
Blanking A End
Blanking B Begin
Blanking B End
Phase Trigger
Sample Trigger 2
To Other
Modules
To Other
Modules
Leading Edge Closed Loop
Adaptive Sample Trigger A
56
UCD3138064A
SLUSCA5B – DECEMBER 2015 – REVISED JANUARY 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: UCD3138064A
Detailed Description
Copyright © 2015–2017, Texas Instruments Incorporated
Events which change with DPWM mode:
DPWM A Falling Edge = Event 1
DPWM A Rising Edge = Event 1 – Filter Duty + Cycle Adjust A
Adaptive Sample Trigger A = Event 1 – Filter Duty + Adaptive Sample Register or
Adaptive Sample Trigger B = Event 1 – Filter Duty/2 + Adaptive Sample Register
DPWM B Rising Edge = Event 4
DPWM B Falling Edge = Event 1 – Filter Duty + Cycle Adjust A – (Event 2 – Event 3)
Phase Trigger = Phase Trigger Register value or Filter Duty
Events always set by their registers, regardless of mode:
Sample Trigger 1, Sample Trigger 2, Blanking A Begin, Blanking A End,
Blanking B Begin, Blanking B End
Figure 6-31. Leading Edge Mode
As in the Normal mode, the two edges in the middle of the period are dynamic, so the fixed blanking
intervals are mainly useful for the edges at the beginning and end of the period.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com