| Os motores de busca de Datasheet de Componentes eletrônicos |
|
UCD3138064ARGCR.A Folha de dados(PDF) 38 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
UCD3138064ARGCR.A Folha de dados(HTML) 38 Page - Texas Instruments |
|
38 / 84 page ![]() 18 24 14 38 18 KCompx DPWMx Period Loop_VFF Filter YN (Duty %) Filter Duty S0.23 14.0 14.0 14.0 14.0 S14.23 Resonant Duty 14.0 Round to 18 bits, Clamp to Positive Clamp Filter Output Clamp High Filter Output Clamp Low X 14.4 14.4 OUTPUT_MULT_SEL 14 Bits [17:4] Filter Period 24 14 38 18 KCompx DPWMx Period Filter YN S0.23 14.0 14.0 14.0 S14.23 Round to 18 bits, Clamp to Positive Truncate low 4 bits X 14.0 PERIOD_MULT_SEL 14.4 38 UCD3138064A SLUSCA5B – DECEMBER 2015 – REVISED JANUARY 2017 www.ti.com Submit Documentation Feedback Product Folder Links: UCD3138064A Detailed Description Copyright © 2015–2017, Texas Instruments Incorporated There is a final section for the filter, shown in Figure 6-16 that permits its output to be matched to the DPWM: Figure 6-16. Final Section for the Filter This permits the filter output to be multiplied by a variety of correction factors to match the DPWM Period, to provide for Voltage Feed Forward, or for other purposes. After this, there is another clamp. For resonant mode, the filter can be used to generate both period and duty cycle. 6.4.6.1 Loop Multiplexer The Loop Mux controls interconnections between the filters, front ends, and DPWMs. Any filter, front end, and DPWM can be combined in a variety of configurations. It also controls the following connections: • DPWM to Front End • Front End DAC control from Filters or Constant Current/Constant Power Module • Filter Special Coefficients and Feed Forward • DPWM synchronization • Filter to DPWM The following control modules are configured in the Loop Mux: • Constant Power/Constant Current • Cycle Adjustment (Current and flux balancing) • Global Period • Light Load (Burst Mode) • Analog Peak Current Mode 6.4.6.2 Fault Multiplexer In order to allow a flexible way of mapping several fault triggering sources to all the DPWMs channels, the UCD3138x provides an extensive array of multiplexers that are united under the name Fault Mux module. The Fault Mux Module supports the following types of mapping between all the sources of fault and all the different fault response mechanisms inside each DPWM module. • Many fault sources may be mapped to a single fault response mechanism. For instance an analog comparator in charge of over voltage protection, a digital comparator in charge of over current protection and an external digital fault pin can be all mapped to a Fault-A signal connected to a single FAULT MODULE and shut down DPWM1-A. • A single fault source can be mapped to many fault response mechanisms inside many DPWM modules. For instance an analog comparator in charge of over current protection can be mapped to DPWM-0 through DPWM-3 by way of several fault modules. • Many fault sources can be mapped to many fault modules inside many DPWM modules. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |