| Os motores de busca de Datasheet de Componentes eletrônicos |
|
DSPIC30F6010 Folha de dados(PDF) 42 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DSPIC30F6010 Folha de dados(HTML) 42 Page - Microchip Technology |
|
42 / 222 page ![]() dsPIC30F6010 DS70119E-page 40 © 2006 Microchip Technology Inc. Address Error Trap: This trap is initiated when any of the following circumstances occurs: 1. A misaligned data word access is attempted. 2. A data fetch from our unimplemented data memory location is attempted. 3. A data access of an unimplemented program memory location is attempted. 4. An instruction fetch from vector space is attempted. 5. Execution of a “BRA #literal” instruction or a “GOTO #literal” instruction, where literal is an unimplemented program memory address. 6. Executing instructions after modifying the PC to point to unimplemented program memory addresses. The PC may be modified by loading a value into the stack and executing a RETURN instruction. Stack Error Trap: This trap is initiated under the following conditions: 1. The Stack Pointer is loaded with a value which is greater than the (user programmable) limit value written into the SPLIM register (stack overflow). 2. The Stack Pointer is loaded with a value which is less than 0x0800 (simple stack underflow). Oscillator Fail Trap: This trap is initiated if the external oscillator fails and operation becomes reliant on an internal RC backup. 5.3.2 HARD AND SOFT TRAPS It is possible that multiple traps can become active within the same cycle (e.g., a misaligned word stack write to an overflowed address). In such a case, the fixed priority shown in Figure 5-2 is implemented, which may require the user to check if other traps are pending, in order to completely correct the fault. ‘Soft’ traps include exceptions of priority level 8 through level 11, inclusive. The arithmetic error trap (level 11) falls into this category of traps. ‘Hard’ traps include exceptions of priority level 12 through level 15, inclusive. The address error (level 12), stack error (level 13) and oscillator error (level 14) traps fall into this category. Each hard trap that occurs must be acknowledged before code execution of any type may continue. If a lower priority hard trap occurs while a higher priority trap is pending, acknowledged, or is being processed, a hard trap conflict will occur. The device is automatically Reset in a hard trap conflict condition. The TRAPR status bit (RCON<15>) is set when the Reset occurs, so that the condition may be detected in software. FIGURE 5-1: TRAP VECTORS Note: In the MAC class of instructions, wherein the data space is split into X and Y data space, unimplemented X space includes all of Y space, and unimplemented Y space includes all of X space. Address Error Trap Vector Oscillator Fail Trap Vector Stack Error Trap Vector Reserved Vector Math Error Trap Vector Reserved Oscillator Fail Trap Vector Address Error Trap Vector Reserved Vector Reserved Vector Interrupt 0 Vector Interrupt 1 Vector — — — Interrupt 52 Vector Interrupt 53 Vector Math Error Trap Vector 0x000000 0x000014 Reserved Stack Error Trap Vector Reserved Vector Reserved Vector Interrupt 0 Vector Interrupt 1 Vector — — — Interrupt 52 Vector Interrupt 53 Vector IVT AIVT 0x000080 0x00007E 0x0000FE Reserved 0x000094 Reset - GOTO Instruction Reset - GOTO Address 0x000002 Reserved 0x000082 0x000084 0x000004 Reserved Vector |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |