| Os motores de busca de Datasheet de Componentes eletrônicos |
|
BMP280 Folha de dados(PDF) 26 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP280 Folha de dados(HTML) 26 Page - Bosch Sensortec GmbH |
|
26 / 49 page ![]() Bosch Sensortec | BMP280 Data sheet 26 | 49 Modifications reserved | Data subject to change without notice Document number: BST-BMP280-DS001-26 Revision_1.26_102021 Table 22: register settings osrs_t osrs_t[2:0] Temperature oversampling 000 Skipped (output set to 0x80000) 001 oversampling ×1 010 oversampling ×2 011 oversampling ×4 100 oversampling ×8 101, 110, 111 oversampling ×16 4.3.5 Register 0xF5 “config” The “config” register sets the rate, filter and interface options of the device. Writes to the “config” register in normal mode may be ignored. In sleep mode writes are not ignored. Table 23: Register 0xF5 “config” Register 0xF5 “config” Name Description Bit 7, 6, 5 t_sb[2:0] Controls inactive duration tstandby in normal mode. See chapter 3.6.3 for details. Bit 4, 3, 2 filter[2:0] Controls the time constant of the IIR filter. See chapter 3.3.3 for details. Bit 0 spi3w_en[0] Enables 3-wire SPI interface when set to ‘1’. See chapter 5.3 for details. 4.3.6 Register 0xF7…0xF9 “press” (_msb, _lsb, _xlsb) The “press” register contains the raw pressure measurement output data up[19:0]. For details on how to read out the pressure and temperature information from the device, please consult chapter0. Table 24: Register 0xF7 … 0xF9 “press” Register 0xF7- 0xF9 “press” Name Description 0xF7 press_msb[7:0] Contains the MSB part up[19:12] of the raw pressure measurement output data. 0xF8 press_lsb[7:0] Contains the LSB part up[11:4] of the raw pressure measurement output data. 0xF9 (bit 7, 6, 5, 4) press_xlsb[3:0] Contains the XLSB part up[3:0] of the raw pressure measurement output data. Contents depend on temperature resolution, see table 5. 4.3.7 Register 0xFA…0xFC “temp” (_msb, _lsb, _xlsb) The “temp” register contains the raw temperature measurement output data ut[19:0]. For details on how to read out the pressure and temperature information from the device, please consult chapter 0. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |