18 / 78 page ![]() Data Sheet ADIN1100 THEORY OF OPERATION analog.com Rev. 0 | 18 of 78 Master/Slave Advertisement Master/Slave Configuration Advertisement The master/slave configuration register bit (AN_ADV_MST) is used to configure the PHY to advertise its master/slave configuration. Note that this bit is configured after power-up, hardware reset, or software reset based on the MS_SEL configuration pin signal status and can be overridden by software via the MDIO interface. Forced Master/Slave Configuration Advertisement If it is mandatory for the PHY to operate as a master (or slave), use the advertise forced configuration. Forced configuration must be used with caution because a configuration fault can occur if the link partner is also set in forced mode as a master (or slave) resulting in autonegotiation failure. The ADIN1100 can be forced to operate as a master or slave using the force master/slave configuration register bit (AN_ADV_FORCE_MS). Read Link Partner Master/Slave Configuration The link partner advertised master/slave setting can be read using the following bits: ► AN_LP_ADV_FORCE_MS: link partner force master/slave con- figuration register bit ► AN_LP_ADV_MST: link partner master/slave configuration regis- ter bit These bits are updated during the autonegotiation process and are valid when the autonegotiation complete register bit (AN_COM- PLETE) is set. Master/Slave Resolution Determination of Master/Slave Configuration When the local and remote PHYs have the same preferred config- uration, for example, both slave or both master, autonegotiation randomly assigns compatible configurations to the local and remote PHYs. When one PHY has a forced configuration, its master/slave configuration is given priority over a PHY with a preferred setting. Master/Slave Configuration Resolution The ADIN1100 master/slave configuration defined by the autonego- tiation can be checked using the master/slave resolution result register bits (AN_MS_CONFIG_RSLTN). The bits indicate if the PHY is configured as master or slave or if there was a configuration fault. These bits are updated during the autonegotiation process and are valid when the autonegotiation complete register bit (AN_COM- PLETE) is set. Table 12. Determination of Master/Slave by Autonegotiation Local1 Remote1 Local Remote AN_ADV_FORCE_MS AN_ADV_MST AN_LP_ADV_FORCE_MS AN_LP_ADV_MST Master/Slave Resolution 0 0 0 0 Master/slave Slave/master 0 0 0 1 Slave Master 0 1 0 0 Master Slave 0 1 0 1 Master/slave Slave/master 0 X 1 0 Master Slave 0 X 1 1 Slave Master 1 0 0 X Slave Master 1 1 0 X Master Slave 1 0 1 0 Configuration fault Configuration fault 1 0 1 1 Slave Master 1 1 1 0 Master Slave 1 1 1 1 Configuration fault Configuration fault 1 X means don't care. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |