69 / 84 page ![]() 20.0 Instruction Set (Continued) Indirect from Program Memory. This is a special case of an indirect instruction that allows access to data tables stored in program memory. In the “Load Accumulator Indi- rect” (LAID) instruction, the upper and lower bytes of the Program Counter (PCU and PCL) are used temporarily as a pointer to program memory. For purposes of accessing pro- gram memory, the contents of the Accumulator and PCL are exchanged. The data pointed to by the Program Counter is loaded into the Accumulator, and simultaneously, the original contents of PCL are restored so that the program can re- sume normal execution. Example: Load Accumulator Indirect LAID Reg/Data Contents Contents Memory Before After PCU 04 Hex 04 Hex PCL 35 Hex 36 Hex Accumulator 1F Hex 25 Hex Memory Location 25 Hex 25 Hex 041F Hex 20.3.2 Tranfer-of-Control Addressing Modes Program instructions are usually executed in sequential or- der. However, Jump instructions can be used to change the normal execution sequence. Several transfer-of-control ad- dressing modes are available to specify jump addresses. A change in program flow requires a non-incremental change in the Program Counter contents. The Program Counter consists of two bytes, designated the upper byte (PCU) and lower byte (PCL). The most significant bit of PCU is not used, leaving 15 bits to address the program memory. Different addressing modes are used to specify the new address for the Program Counter. The choice of addressing mode depends primarily on the distance of the jump. Farther jumps sometimes require more instruction bytes in order to completely specify the new Program Counter contents. The available transfer-of-control addressing modes are: • Jump Relative • Jump Absolute • Jump Absolute Long • Jump Indirect The transfer-of-control addressing modes are described be- low. Each description includes an example of a Jump in- struction using a particular addressing mode, and the effect on the Program Counter bytes of executing that instruction. Jump Relative. In this 1-byte instruction, six bits of the instruction opcode specify the distance of the jump from the current program memory location. The distance of the jump can range from −31 to +32. A JP+1 instruction is not allowed. The programmer should use a NOP instead. Example: Jump Relative JP 0A Reg Contents Contents Before After PCU 02 Hex 02 Hex PCL 05 Hex 0F Hex Jump Absolute. In this 2-byte instruction, 12 bits of the instruction opcode specify the new contents of the Program Counter. The upper three bits of the Program Counter re- main unchanged, restricting the new Program Counter ad- dress to the same 4-kbyte address space as the current instruction. (This restriction is relevant only in devices using more than one 4-kbyte program memory space.) Example: Jump Absolute JMP 0125 Reg Contents Contents Before After PCU 0C Hex 01 Hex PCL 77 Hex 25 Hex Jump Absolute Long. In this 3-byte instruction, 15 bits of the instruction opcode specify the new contents of the Pro- gram Counter. Example: Jump Absolute Long JMP 03625 Reg/ Contents Contents Memory Before After PCU 42 Hex 36 Hex PCL 36 Hex 25 Hex Jump Indirect. In this 1-byte instruction, the lower byte of the jump address is obtained from a table stored in program memory, with the Accumulator serving as the low order byte of a pointer into program memory. For purposes of access- ing program memory, the contents of the Accumulator are written to PCL (temporarily). The data pointed to by the Program Counter (PCH/PCL) is loaded into PCL, while PCH remains unchanged. Example: Jump Indirect JID Reg/ Contents Contents Memory Before After PCU 01 Hex 01 Hex PCL C4 Hex 32 Hex Accumulator 26 Hex 26 Hex Memory Location 32 Hex 32 Hex 0126 Hex The VIS instruction is a special case of the Indirect Transfer of Control addressing mode, where the double-byte vector associated with the interrupt is transferred from adjacent addresses in program memory into the Program Counter in order to jump to the associated interrupt service routine. 20.4 INSTRUCTION TYPES The instruction set contains a wide variety of instructions. The available instructions are listed below, organized into related groups. Some instructions test a condition and skip the next instruc- tion if the condition is not true. Skipped instructions are executed as no-operation (NOP) instructions. www.national.com 69 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |