| Os motores de busca de Datasheet de Componentes eletrônicos |
|
UCD3138ARMHT Folha de dados(PDF) 43 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
UCD3138ARMHT Folha de dados(HTML) 43 Page - Texas Instruments |
|
43 / 87 page ![]() CYCLE BY CYCLE CLIM FAULT - CBC FAULT MODULE FAULT IN FAULT FLAG 43 UCD3138A www.ti.com SLUSC66C – MARCH 2015 – REVISED SEPTEMBER 2016 Submit Documentation Feedback Product Folder Links: UCD3138A Detailed Description Copyright © 2015–2016, Texas Instruments Incorporated The Fault Mux Module provides a multitude of fault protection functions within the UCD3138A high-speed loop (front end control, filter, DPWM and loop Mux modules). The Fault Mux Module allows highly configurable fault generation based on digital comparators, high-speed analog comparators and external fault pins. Each of the fault inputs to the DPWM modules can be configured to one or any combination of the fault events provided in the Fault Mux Module. Each one of the DPWM engines has four fault modules. The modules are called CBC fault module, AB fault module, A fault module and B fault module. The internal circuitry in all the four fault modules is identical, and the difference between the modules is limited to the output it affects under a fault condition. Figure 7-10. Fault Module All fault modules are capable of detecting faults only once per DPWM switching cycle. Each one of the fault modules have a separate max_count value and the device sets the fault flag only when the sequential faults count exceeds the max_count value. After the fault flag is set, DPWMs must be disabled by DPWM_EN going low in order to clear the fault flags. NOTE All four fault modules share the same DPWM_EN control. The device clears all fault flags (output of fault modules) simultaneously. All four Fault Modules share the same global FAULT_EN as well. Therefore, a specific Fault Module cannot be enabled/ disabled separately. Figure 7-11. Cycle by Cycle Block In contrast to the fault modules, only one cycle by cycle block is available in each DPWM module. The cycle by cycle block can work in conjunction with CBC Fault Module and enables DPWM reaction to signals arriving from analog peak current mode (PCM) module. The fault Mux module supports the following basic functions: • 4 digital comparators with programmable thresholds and fault generation • Configuration for 7 high-speed analog comparators with programmable thresholds and fault generation • External GPIO detection control with programmable fault generation • Configurable DPWM fault generation for DPWM current limit fault, DPWM overvoltage detection fault, DPWM A external fault, DPWM B external fault and DPWM IDE flag • Clock failure detection for high and low frequency oscillator blocks |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |