23 / 27 page ![]() AD7994/AD7993 –23– REV. PrF PRELIMINARYTECHNICAL DATA Figure 14. Reading two bytes of data from the Conversion Result Register Figure 13. Reading a single byte of data from a selected register device will win communication rights via standard I 2C arbitration during the slave address transfer. The ALERT output becomes active when the value in the Conversion Result Register exceeds the value in the DATAHIGH Register or falls below the value in the DATALOW Register . It is reset when a write operation to the Configuration register sets D1 to a 1, or when the conversion result returns N LSBs below or above the value stored in the DATAHIGH Register or DATALOW Register respectively. N is the value in the Hysteresis register. (See Limit Registers section) The ALERT output requires an external pull-up resistor. This can be connected to a voltage different from VDD provided the maximum voltage rating of the ALERT out- put pin is not exceeded. The value of the pull-up resistor depends on the application, but should be as large as pos- sible to avoid excessive sink currents at the ALERT out- put. ALERT/BUSY PIN The ALERT/BUSY may be configured as an Alert or Busy ouput as shown in Table VI. SMBus ALERT The AD7994/AD7993 ALERT output is an SMBus inter- rupt line for devices that want to trade their ability to master for an extra pin. The AD7994/AD7993 is a slave only device and uses the SMBus ALERT to signal the host device that it wants to talk. The SMBus ALERT on the AD7994/AD7993 is used as an out of conversion range indicator (a limit violation indicator). The ALERT pin has an open-drain configuration which allows the ALERT outputs of several AD7994/AD7993 devices to be wired-AND together when the ALERT pin is active low. D0 of the Configuration Register is used to set the active polarity of the ALERT output. The power- up default is active low. The ALERT function can be disabled or enabled by setting D2 of the Configuration Register to 1 or 0 respectively. The host device can process the ALERT interrupt and simultaneously access all SMBus ALERT devices through the alert response address. Only the device which pulled the ALERT low will acknowledge the ARA (Alert Re- sponse Address). If more than one device pulls the ALERT pin low, the highest priority (lowest address) SDA NO ACK. BY MASTER START BY MASTER FRAME 1 SERIAL BUS ADDRESS BYTE FRAME 2 SINGLE DATA BYTE FROM AD7994/3 ACK. BY AD7994/3 19 1 9 D7 D6 D5 D2 D1 D0 R/ 9 A0 A1 A2 A3 0 1 SCL STOP BY MASTER D4 D3 0 SDA ACK. BY MASTER START BY MASTER FRAME 1 SERIAL BUS ADDRESS BYTE FRAME 2 MOST SIGNIFICANT DATA BYTE FROM AD7994/3 ACK. BY AD7994/3 19 1 9 Alert_ Flag D10 D9 D8 R/ 9 A0 A1 A2 A3 0 0 SCL 1 D11 NO ACK. BY MASTER FRAME 3 LEAST SIGNIFICANT DATA BYTE FROM AD7994/3 19 D7 D6 D5 D2 D1/0 D0/0 STOP BY MASTER D4 D3 SCL (CONTINUED) SDA (CONTINUED) CH ID1 CH ID0 0 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |