AD7993 Folha de dados(PDF) 19 Page - Analog Devices

Nome de Peças AD7993
Descrição Electrónicos  4-Channel, 12-/10-Bit ADCs with I2C Compatible Interface in 16-Lead TSSOP
PDF  27 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  AD [Analog Devices]
Página de início  http://www.analog.com
Logo AD - Analog Devices

AD7993 Folha de dados(HTML) 19 Page - Analog Devices

Back Button AD7993 Datasheet HTML 15Page - Analog Devices AD7993 Datasheet HTML 16Page - Analog Devices AD7993 Datasheet HTML 17Page - Analog Devices AD7993 Datasheet HTML 18Page - Analog Devices AD7993 Datasheet HTML 19Page - Analog Devices AD7993 Datasheet HTML 20Page - Analog Devices AD7993 Datasheet HTML 21Page - Analog Devices AD7993 Datasheet HTML 22Page - Analog Devices AD7993 Datasheet HTML 23Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 27 page
background image
AD7994/AD7993
–19–
REV. PrF
PRELIMINARYTECHNICAL DATA
Table XIb. Alert Status Register Bit Function
Description
Bit Mnemonic Comment
D 0 CH1LO
Violation of DATALOW limit on Channel
1 if this bit set to 1, no violation if 0.
D 1 CH1HI
Violation of DATAHIGH limit on Chan
nel 1 if this bit set to 1, no violation if 0.
D 2 CH2LO
Violation of DATALOW limit on Channel
2 if this bit set to 1, no violation if 0.
D 3 CH2HI
Violation of DATAHIGH limit on Chan
nel 2 if this bit set to 1, no violation if 0.
D 4 CH3LO
Violation of DATALOW limit on Channel
3 if this bit set to 1, no violation if 0.
D 5 CH3HI
Violation of DATAHIGH limit on Chan
nel 3 if this bit set to 1, no violation if 0.
max conversion results, the Alert_Flag bit, D15, can be
used to indicate that an alert has happened on another one
of the Input channels.
It must be noted that on power-up, the contents of the
DATAHIGH register for each channel will be fullscale,
while the contents of the DATALOW registers will be
zeroscale, by default minimum and maximum conversion
values being stored in this way will be lost if power is
removed or cycled.
When using the limit registers to store the min and max
conversion results, the Alert_Flag bit, D15, is used to
indicate that an alert has happened on another one of the
Input channels. If the Alert_Flag bit is set to 1, it will be
reset when the Conversion result returns to a value at least
N LSBs above the DATALOW Register value or below the
DATALOW Register value or if bits D2 and D1 of the
Configuration Register are set to 1. The Alert_Flag bit in
the limit registers is useful if the user is not reading from
the conversion result register when reading the min and
max conversion results from the limit registers.
ALERT STATUS REGISTER
The Alert Status Register is a 8-bit read/write register,
which provides information on an Alert event. If a conver-
sion results in activating the ALERT pin or the Alert_Flag
bit in the Conversion Result Register, as described in the
Limit Registers section, then the Alert Status Register may
be read to gain further information. It contains 2 status
bits per channel, one corresponding to the DATAHIGH
limit and the other to the DATALOW limit. Whichever bit
has a status of 1 will show where the violation occured, i.e.
on which channel and whether on upper or lower limit. If
a second alert event occurs on the other channel between
receiving the first alert and interrogating the Alert Status
register then the corresponding bit for that Alert event will
be set also.
The entire contents of the Alert Status register may be
cleared by writing 1,1, to bits D2 and D1 in the Configu-
ration register as shown in Table VI. This may also be
acheived by ‘writing’ all 1’s to the Alert Status Register
itself. This means that if the Alert Status Register is ad-
dressed for a write operation which is all 1’s, then the
contents of the Alert Status Register will then be cleared
or resest to all 0’s. Alternatively, an individual active Alert
bit(s) may be reset within the Alert Status Register by
performing a write of ‘1’ to that bit alone. The advantage
of this is that once an Alert event has been serviced, that
particular bit can be reset, e.g. CH1LO, without clearing
the entire contents of the Alert Status Register, thus pre-
serving the status of any additional Alert, e.g. CH2HI,
which may have occured while servicing the first. If it is
not necessary to clear an Alert directly after servicing then
obviously the Alert Status register may be read again im-
mediately to look for any new Alerts, bearing in mind that
the one just serviced will still be active.
Table XIa. Alert Status Register
D7
D6
D5
D4
D3
D2
D1
D0
CH4HI CH4LO CH3HI CH3LOCH2HI CH2LOCH1HI CH1LO
D 6 CH4LO
Violation of DATALOW limit on Channel
4 if this bit set to 1, no violation if 0.
D 7 CH4HI
Violation of DATAHIGH limit on Chan
nel 4 if this bit set to 1, no violation if 0.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com