MTC600 Folha de dados(PDF) 4 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
MTC600 Folha de dados(HTML) 4 Page - Emerson Network Power |
|
4 / 19 page ![]() Output - All Models (continued) 12 V Outputs (Payload Power)1,2 Management Power Interdependence 12 V will not be applied without 3.3 V applied to a load Removal of 3.3 V also removes 12 V and de-asserts ENABLE# Setpoint 12.6 Vdc typical 11.8 Vdc typical Configured as Primary PM Configured as Redundant PM Total Regulation Range 12.25 to 12.95 Vdc 11.60 to 12.00 Vdc Configured as Rrimary PM Configured as Redundant PM Rated Load 600 W maximum 80 W / 7.6 A maximum Per Power Module, input voltage ≥110 Vac Per load channel Minimum Load No load No loss of regulation ≥110 Vrms Output Rise TIme (per channel) 25 ms maximum With 1600 μF on output under test Output Noise (PARD)3 75 mV maximum 100 mV maximum 0 to 30 MHz 0 to 100 MHz Output Voltage Overshoot 2% maximum Referenced to setpoint Transient Response 3% maximum deviation 2 ms recovery time 2 A loadstep @ 1 A/μs Referenced to load current and setpoint at onset of transient. Recovery time to within 1% of setpoint at onset of transient Voltage Sag 1.00 V maximum Primary PM to redundant PM transition with maximum of 80 W load per output or 600 W load per PM Short Circuit Protection 9.7 A maximum 10 ms maximum Output to return Channel Fault Operation (Output to Return) 12V Payload Power Output under fault is shutdown. 3V3 MP on the same channel is not affected. The other channels are not affected After removal of fault, the output channel is available again under control of the Carrier Manager. PM_OK# is not de-asserted and redundant failover is not initiated Channel Fault Operation (Output to Output) No damage to Power Module Either or both outputs may shut down until fault is removed PS1# Extraction Delay 100 μs maximum Time from de-assertion of PS1# to disabling of the channel outputs and de-assertion of the ENABLE# signal Reflected Ripple Tolerance on Cooling Unit Outputs4 100 mV pk-pk 0.8 A pk-pk Tolerance of Power Module to ripple generated by fans or motors connected to Payload Power on Cooling Units Embedded Power for Business-Critical Continuity Rev. 05.26.08 MTC600 Series 4 of 19 Note 1: All channels and outputs must be configued by the carrier manager with the exception of MCH and CU channels and outputs which are configured during Startup and/or autonomous operation, Note 2: All measurements are made at the output connector of the Power Module. Unless otherwise specified,specs apply to all AMC, MCH, and CU outputs. Note 3: Measured with a 0.1 μF ceramic and 10 μF tantalum capacitor on any output and oscilloscope bandwidth set for 200 MHz. Note 4: Consult with the factory if other outputs are expected to product significant ripple current. Electrical Specifications (continued) |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |