5 / 19 page ![]() Rev. 05.26.08 MTC600 Series 5 of 19 Embedded Power for Business-Critical Continuity Output - All Models (continued) 3.3 V Outputs (Management Power) 5,6 Payload Power Interdependence 3.3 V must be applied before 12 V Removal of 3.3 V also removes 12 V and de-asserts ENABLE# Setpoint 3.3 Vdc typical Total Regulation Range 3.16 to 3.63 Vdc Rated Load 8 W maximum 0.5 W / 150 mA maximum Per Power Module Per load channel Minimum Load No load No loss of regulation Output Rise TIme (per channel) 25 ms maximum With 150 μF on output under test Output Noise (PARD)3 50 mV maximum 75 mV maximum 0 to 30 MHz 0 to 100 MHz Output Voltage Overshoot 2% maximum Referenced to setpoint Transient Response 3% maximum deviation 2 ms recovery time 37.5 mA loadstep @ 1 A/μs Referenced to load current and setpoint at onset of transient. Recovery time to within 1% of setpoint at onset of transient Voltage Sag 150 mV maximum Primary PM to redundant PM transition with max of 80 W load per output or 600 W load per PM Short Circuit Protection 225 mA maximum 12 ms maximum Output to return Channel Fault Operation (Output to Return) Output channel under fault is shutdown. Both 3.3V and 12V are removed and ENABLE# is de-asserted. The other channels are not affected After removal of fault, the output channel is available again under control of the Carrier Manager. PM_OK# is not de-asserted and redundant failover is not initiated Channel Fault Operation (Output to Output) No damage to Power Module Either or both channels may shut down until fault is removed PS1# Extraction Delay 100 μs maximum Time from de-assertion of PS1# to disabling of the channel outputs and de-assertion of the ENABLE# signal Note 5: All channels and outputs must be configued by the carrier manager with the exception of MCH and CU channels and outputs which are configured during Startup and/or autonomous operation. Note 6: All measurements are made at the output connector of the Power Module. Unless otherwise specified,specs apply to all AMC, MCH, and CU outputs. Electrical Specifications (continued) |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |