| Os motores de busca de Datasheet de Componentes eletrônicos |
|
IC42S16100 Folha de dados(PDF) 35 Page - Integrated Circuit Solution Inc |
|
|
|||||||||||||||||||||||||||||
IC42S16100 Folha de dados(HTML) 35 Page - Integrated Circuit Solution Inc |
|
35 / 78 page ![]() IC42S16100 Integrated Circuit Solution Inc. 35 DR024-0D 06/25/2004 CAS latency = 2, burst length = 4 READ 0 COMMAND CKE I/O CLK DOUT 0DOUT 1DOUT 2DOUT 3 READ (BANK 0) CLOCK SUSPEND Bank Active Command Interval When the selected bank is precharged, the period trp has elapsed and the bank has entered the idle state, the bank can be activated by executing the active command. If the other bank is in the idle state at that time, the active command can be executed for that bank after the period tRRD has elapsed. At that point both banks will be in the active state. When a bank active command has been executed, a precharge command must be executed for that bank within the ACT to PRE command period (tRAS max). Also note that a precharge command cannot be executed for an active bank before tRAS (min) has elapsed. After a bank active command has been executed and the trcd period has elapsed, read write (including auto- precharge) commands can be executed for that bank. ACT 0 ACT 1 COMMAND CLK BANK ACTIVE (BANK 0) BANK ACTIVE (BANK 1) tRRD ACT 0 READ 0 COMMAND CLK BANK ACTIVE (BANK 0) BANK ACTIVE (BANK 0) tRCD Clock Suspend When the CKE pin is dropped from HIGH to LOW during a read or write cycle, the IC42S16100 enters clock suspend mode on the next CLK rising edge. This command reduces the device power dissipation by stopping the device internal clock. Clock suspend mode continues as long as the CKE pin remains low. In this state, all inputs other than CKE pin are invalid and no other commands can be executed. Also, the device internal states are maintained. When the CKE pin goes from LOW to HIGH clock suspend mode is terminated on the next CLK rising edge and device operation resumes. The next command cannot be executed until the recovery period (tCKA) has elapsed. Since this command differs from the self-refresh command described previously in that the refresh operation is not performed automatically internally, the refresh operation must be performed within the refresh period (tref). Thus the maximum time that clock suspend mode can be held is just under the refresh cycle time. CAS latency = 3 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |