| Os motores de busca de Datasheet de Componentes eletrônicos |
|
CD5.242 Folha de dados(PDF) 18 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CD5.242 Folha de dados(HTML) 18 Page - PULS GmbH |
|
18 / 22 page ![]() CD5.242 CD-Series DC/DC Converter 24V, 5A 21. APPLICATION NOTES 21.1. PEAK CURRENT CAPABILITY Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current (including the PowerBoost) The same situation applies, when starting a capacitive load. Branch circuits are often protected with circuit breakers or fuses. In case of a short or an overload in the branch circuit, the fuse needs a certain amount of over-current to trip or to blow. The peak current capability ensures the safe operation of subsequent circuit breakers. Assuming the input voltage is turned on before such an event, the built-in large sized output capacitors inside the DC/DC converter can deliver extra current. Discharging this capacitor causes a voltage dip on the output. The following two examples show typical voltage dips: Fig. 21-1 Peak loading with 2x the nominal current for 50ms, typ. Fig. 21-2 Peak loading with 4x the nominal current for 5ms, typ. Output Voltage 24V 18/22 10ms/DIV Output Current 0.7A 10A 17.1V 24V Output Voltage Output Current 0.7A 1ms/DIV 20A 11V Peak load 10A (resistive load) for 50ms Output voltage dips from 24V to 17.1V. Peak load 20A (resistive load) for 5ms Output voltage dips from 24V to 11V. 21.2. BACK-FEEDING LOADS Loads such as decelerating motors and inductors can feed voltage back to the DC/DC converter. This feature is also called return voltage immunity or resistance against Back- E.M.F. (Electro Magnetic Force). This DC/DC converter is resistant and does not show malfunctioning when a load feeds back voltage to the DC/DC converter. It does not matter, whether the DC/DC converter is on or off. The maximum allowed feed-back-voltage is 30Vdc. The absorbing energy can be calculated according to the built-in large sized output capacitance which is specified in chapter 5. 21.3. INDUCTIVE AND CAPACITIVE LOADS The unit is designed to supply any kind of loads, including unlimited capacitive and inductive loads. Mar. 2016 / Rev. 1.5 DS-CD5.242-EN All parameters are specified at 24V, 5A, 48Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |