| Os motores de busca de Datasheet de Componentes eletrônicos |
|
AD9518-2ABCPZ Folha de dados(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9518-2ABCPZ Folha de dados(HTML) 22 Page - Analog Devices |
|
22 / 64 page ![]() AD9518-2 Data Sheet Rev. C | Page 22 of 64 THEORY OF OPERATION OPERATIONAL CONFIGURATIONS The AD9518 can be configured in several ways. These configurations must be set up by loading the control registers (see Table 42 and Table 43 through Table 49). Each section or function must be individually programmed by setting the appropriate bits in the corresponding control register or registers. High Frequency Clock Distribution—CLK or External VCO > 1600 MHz The AD9518 power-up default configuration has the PLL powered off and the routing of the input set so that the CLK/CLK input is connected to the distribution section through the VCO divider (divide-by-2/divide-by-3/divide-by-4/ divide-by-5/divide- by-6). This is a distribution-only mode that allows for an external input up to 2.4 GHz (see Table 3). The maximum frequency that can be applied to the channel dividers is 1600 MHz; therefore, higher input frequencies must be divided down before reaching the channel dividers. This input routing can also be used for lower input frequencies, but the minimum divide is 2 before the channel dividers. When the PLL is enabled, this routing also allows the use of the PLL with an external VCO or VCXO with a frequency of less than 2400 MHz. In this configuration, the internal VCO is not used and is powered off. The external VCO/VCXO feeds directly into the prescaler. The register settings shown in Table 20 are the default values of these registers at power-up or after a reset operation. If the contents of the registers are altered by prior programming after power-up or reset, these registers can also be set intentionally to these values. After the appropriate register values are programmed, Register 0x232 must be set to 0x01 for the values to take effect. Table 20. Default Settings of Some PLL Registers Register Function 0x010[1:0] = 01b PLL asynchronous power-down (PLL off). 0x1E0[2:0] = 010b Set VCO divider = 4. 0x1E1[0] = 0b Use the VCO divider. 0x1E1[1] = 0b CLK selected as the source. When using the internal PLL with an external VCO, the PLL must be turned on. Table 21. Settings When Using an External VCO Register Function 0x010[1:0] = 00b PLL normal operation (PLL on). 0x010 to 0x01D PLL settings. Select and enable a reference input; set R, N (P, A, B), PFD polarity, and ICP, according to the intended loop configuration. 0x1E1[1] = 0b CLK selected as the source. An external VCO requires an external loop filter that must be connected between CP and the tuning pin of the VCO. This loop filter determines the loop bandwidth and stability of the PLL. Make sure to select the proper PFD polarity for the VCO being used. Table 22. Setting the PFD Polarity Register Function 0x010[7] = 0b PFD polarity positive (higher control voltage produces higher frequency). 0x010[7] = 1b PFD polarity negative (higher control voltage produces lower frequency). |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |