| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ST7263B Folha de dados(PDF) 83 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7263B Folha de dados(HTML) 83 Page - STMicroelectronics |
|
83 / 132 page ![]() ST7263B 83/132 I²C BUS INTERFACE (Cont’d) I²C STATUS REGISTER 2 (SR2) Read Only Reset Value: 0000 0000 (00h) Bits 7:5 = Reserved. Forced to 0 by hardware. Bit 4 = AF Acknowledge failure. This bit is set by hardware when no acknowledge is returned. An interrupt is generated if ITE=1. It is cleared by software reading SR2 register or by hardware when the interface is disabled (PE=0). The SCL line is not held low while AF=1. 0: No acknowledge failure 1: Acknowledge failure Bit 3 = STOPF Stop detection (Slave mode). This bit is set by hardware when a Stop condition is detected on the bus after an acknowledge (if ACK=1). An interrupt is generated if ITE=1. It is cleared by software reading SR2 register or by hardware when the interface is disabled (PE=0). The SCL line is not held low while STOPF=1. 0: No Stop condition detected 1: Stop condition detected Bit 2 = ARLO Arbitration lost. This bit is set by hardware when the interface los- es the arbitration of the bus to another master. An interrupt is generated if ITE=1. It is cleared by soft- ware reading SR2 register or by hardware when the interface is disabled (PE=0). After an ARLO event the interface switches back automatically to Slave mode (M/SL=0). The SCL line is not held low while ARLO=1. 0: No arbitration lost detected 1: Arbitration lost detected Bit 1 = BERR Bus error. This bit is set by hardware when the interface de- tects a misplaced Start or Stop condition. An inter- rupt is generated if ITE=1. It is cleared by software reading SR2 register or by hardware when the in- terface is disabled (PE=0). The SCL line is not held low while BERR=1. 0: No misplaced Start or Stop condition 1: Misplaced Start or Stop condition Bit 0 = GCAL General Call (Slave mode). This bit is set by hardware when a general call ad- dress is detected on the bus while ENGC=1. It is cleared by hardware detecting a Stop condition (STOPF=1) or when the interface is disabled (PE=0). 0: No general call address detected on bus 1: general call address detected on bus 70 0 0 0 AF STOPF ARLO BERR GCAL |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |