| Os motores de busca de Datasheet de Componentes eletrônicos |
|
E39-R3 Folha de dados(PDF) 31 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R3 Folha de dados(HTML) 31 Page - Omron Electronics LLC |
|
31 / 64 page ![]() E3X E3X 31 Nomenclature E3X-T jj E3X-H11 Note: Set the mode selector to L-ON or D-ON after the light axis is adjusted. Stable Operation Indicator (Green Indicator) Light Reception Indicator (Red In- dicator) 8-turn Sensitivity Adjuster Sensitivity Indicator Sensitivity adjustment can be checked visually. E3X-A11/-A41 E3X-VG11 E3X-A21/-A51 E3X-F21/-F51 E3X-VG21 Stable Operation Indicator (Green Indicator) Tuning Indicator (Two Colors: red/green indicator) Tuning Button Operation Mode Selector L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Light Reception Indicator (Red Indicator) Mode Setting Selector Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Light Reception Monitoring Terminal (see note) Monitoring is used with the E39-VX Beam Checker Note: The light reception monitoring terminal is not available with the E3X-T11. Stable Operation Indicator (Green Indicator) Sensitivity Indicator The position of the indicator can be checked. 8-turn Sensitivity Adjuster Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not re- ceived. Light Reception Indicator (Red Indicator) Hysteresis Adjuster Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not re- ceived. Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not re- ceived. Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker Stable Operation Indicator (Green Indicator) Sensitivity Indicator 8-turn Sensitivity Adjuster Light Reception Indicator (Red Indicator) Timer Adjuster |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |