| Os motores de busca de Datasheet de Componentes eletrônicos |
|
UCS1003-3 Folha de dados(PDF) 48 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1003-3 Folha de dados(HTML) 48 Page - Microchip Technology |
|
48 / 138 page ![]() UCS1003-1/2/3 DS20005346B-page 48 2014-2015 Microchip Technology Inc. If the RTN_EN control bit is set to ‘0’ prior to reaching the charge rationing threshold, rationing will be dis- abled and the Total Accumulated Charge registers will be cleared. If the RTN_EN bit is set to ‘0’ after the charge rationing threshold has been reached, the following will be done: 1. RATION status bit will be cleared. 2. The ALERT# pin will be released if asserted by the rationing circuitry and no other conditions are present. 3. The M1, M2, EM_EN, S0 and PWR_EN controls are checked to determine the power state. See Note 1 in Table 7-4. Setting the RTN_RST control bit to ‘1’ will automatically reset the Total Accumulated Charge registers to 00_00h. If this is done prior to reaching the charge rationing threshold, the data will continue to be accu- mulated, restarting from 00_00h. If this is done after the charge rationing threshold is reached, the UCS1003-1 will take action, as shown in Table 7-3. 7.5 Fault Handling Mechanism The UCS1003-1/2/3 has two modes for handling Faults: • Latch (latch-upon-Fault) • Auto-Recovery (automatically attempt to restore the Active power state after a Fault occurs). If the SMBus is actively utilized, auto-recovery Fault handling is the default error handler, as determined by the LATCHS bit (see Section 10.4.3 “Switch Configuration Register” ). Otherwise, the Fault handling mechanism used depends on the state of the LATCH pin. Faults include overcurrent, overvoltage (on VS), undervoltage (on VBUS), back-voltage (VBUS to VS or VBUS to VDD), discharge error and maximum allowable internal die temperature (TTSD) exceeded (see Section 5.1.5 “Error State Operation”). 7.5.1 AUTO-RECOVERY FAULT HANDLING When the LATCH control is low, auto-recovery Fault handling is used. When an error condition is detected, the UCS1003-1/2/3 will immediately enter the Error state and assert the ALERT# pin (see Section 5.1.5 “Error State Operation” ). Independently from the host controller, the UCS1003-1/2/3 will wait a preset time (tCYCLE), check error conditions (tTST) and restore Active operation if the error condition(s) no longer exist. If all other conditions that may cause the ALERT# pin to be asserted have been removed, the ALERT# pin will be released. Note: If the rationing behavior was set to “Report and Disconnect” when the charge rationing threshold was reached, and then the RTN_EN bit is cleared, the portable device may start charging sub-optimally because the charger emulation profile has been removed. Toggle the PWR_EN control to restart charger emulation. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |