Back Button AN3023 Datasheet HTML 15Page - STMicroelectronics AN3023 Datasheet HTML 16Page - STMicroelectronics AN3023 Datasheet HTML 17Page - STMicroelectronics AN3023 Datasheet HTML 18Page - STMicroelectronics AN3023 Datasheet HTML 19Page - STMicroelectronics AN3023 Datasheet HTML 20Page - STMicroelectronics AN3023 Datasheet HTML 21Page - STMicroelectronics AN3023 Datasheet HTML 22Page - STMicroelectronics AN3023 Datasheet HTML 23Page - STMicroelectronics  
Zoom Inzoom in Zoom Outzoom out
 20 / 23 page
background image
Practical application
AN3023
20/23
Doc ID 16113 Rev 1
4.3
Methods for precision improvement
This section presents some hardware and software methods to minimize errors that can
occur in analog-to-digital conversions.
4.3.1
Hardware methods
Analog zooming (use appropriate VREF voltage and VREF offset)
selects reference voltage between input signal ranges
gives full ADC range – minimum voltage per bit
White noise added to measured signal
wobbling of input signal over several bits makes it possible to use averaging (if
input signal is very stable)
white noise gives independence from sampling frequency
Hardware design considerations
grounding
reference voltage filtering
supply filtering
preamplifier usage
frequency independence
4.3.2
Software methods
Averaging samples
averaging decreases speed but can improve accuracy
Digital filtering (50/60 Hz suppression from DC value)
proper sampling frequency to be set (trigger from Timer1 is useful in this case)
software post processing to be performed on sampled data (comb filter)
Fast Fourier Transform (FFT) for AC measurements
shows harmonic parts in measured signal
slower due to more computational power requirements
Calibration of ADC—offset, gain, bit weight calibration
decreases internal ADC errors
internal ADC structure must be known



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com