12 / 23 page ![]() Configuring ADC registers for conversion AN3023 12/23 Doc ID 16113 Rev 1 Practical use Continuous conversion mode is useful for collecting a set of analog values from an external analog signal (for example, to read an AC voltage waveform). Single scan mode Single scan mode is started by triggering a conversion while the SCAN bit is set in the ADC_CR2 register and the CONT bit is 0 in the ADC_CR1 register. The scan is performed from channel 0 up to the channel n programmed in bits CH[3:0] in register ADC_CSR. Do not clear the SCAN bit while the conversion sequence is in progress. Single scan mode can be stopped immediately by clearing the ADON bit in the ADC_CR1 register. Example 3 ● fMASTER = 4 MHz ● fADC = 1 MHz ● Single scan mode from AIN0 to AIN5 channel ● Right alignment ● Starting ADC by software For Example 3, the ADC registers should be configured as follows: ADC_CR1:SPSEL[2:0] = 010 → f ADC = 1 MHz (that is, fMASTER/4) ADC_CSR:CH[3:0] = 0101 → select the scan from AIN0 to AIN5 ADC_CR1:ADON = 1 → ADC power on Wait (14/fADC) → stabilization time before starting the conversion ADC_CR2:SCAN = 1 → scan mode enable ADC_CR2:ALIGN = 1 → right alignment ADC_CR1:ADON = 1 → starting the conversion by software Wait (ADC_CSR:EOC = 1) → end of conversion Read the result of the conversion in ADC_DBxRH and ADC_DBxRL data buffer registers, where x = 0..5. Practical use Single scan mode is useful for collecting different analog values from external sensors. This conversion mode permits a faster conversion operation than the simple single conversion mode (which requires conversion to be performed channel per channel). Continuous scan mode Continuous scan mode is started by triggering a conversion while the SCAN bit is set in the ADC_CR2 register and CONT bit is set in the ADC_CR1 register. The scan is performed from channel 0 up to the channel n programmed in bits CH[3:0], and, when the EOC bit is set, a new scan is started automatically. The data buffer registers must be read before the completion of new scan sequence, otherwise the data buffers are overwritten. Do not clear the SCAN bit while scan conversion is in progress. Continuous scan mode can be stopped immediately by clearing the ADON bit in the ADC_CR1 register. Alternatively, if |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |