31 / 110 page ![]() During normal operation the PWM pins driving is managed by the digital section of the loop controller which is in charge of the TON and TOFF generation along with their minimum value limitations (MFR_T_MIN). In case of fault event, the PWM pin driving is overridden by the diagnostic control which applies to the configured reaction (as instance: 3Tclk turn-off then HIZ, cycle-by-cycle turn-off, etc.). Since fault events are not synchronous with normal PWM generation and since reaction countermeasure shall be applied within a specific fault tolerant time, it turns out that PWM driving by loop and by diagnostic controllers cannot be synchronous as well and diagnostic shall have the highest priority. In case of fault events requiring PWM turn-off or switch to HiZ, the MINIMUM ON/OFF time configured in MFR_T_MIN cannot be guaranteed. Figure 21. Minimum TON clipping during LTC fault reaction t Ton MIN Fault reaction time Fault happens PWM_DIG PWMn DIAG_DIS 3.4.2.3 Ignore faults When a fault whose reaction is set as “ignore” is detected, the related PMBus™ flag is set to ‘1’. Logic performs no corrective action. The PMBus™ flag can be cleared when all the following conditions are met in this sequence: 1. Fault is removed. 2. Clear mechanism - One of the following actions, required by application software: – VR_EN1/VR_EN2 is asserted low for at least T_clear and then asserted back high. – CLEAR_FAULTS command by PMBus™ (clears all faults). – Dedicated clear commands by PMBus™ (clears single fault). Note: • VR1_EN toggling is used to clear specific fault affecting loop 1. VR2_EN toggling is used to clear specific fault affecting loop 2. Generic faults affecting both loops can be cleared by toggling either VR1_EN or VR2_EN. • Faults clearing through the PMBus™ command make use of paging for faults affecting the specific loop. Generic faults affecting both loops can be cleared independently of the command page. STPM098C Functional description DS14440 - Rev 1 page 31/110 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |