Back Button KITFS26AEEVM Datasheet HTML 9Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 10Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 11Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 12Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 13Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 14Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 15Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 16Page - NXP Semiconductors KITFS26AEEVM Datasheet HTML 17Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 60 page
background image
NXP Semiconductors
UM11503
KITFS26AEEVM evaluation board
• VDEBUG < VDBG4TH (VDEBUG < 4.2 V): waive debug entry at power up or after low-
power modes exit.
• VDEBUG > VDBG4TH (VDEBUG > 4.2 V): enter debug mode at power up or after low
power modes exit.
• VDEBUG VDBG65TH (VDEBUG > 6.9 V): burning level for OTP programming.
The power supply to generate the debug entry voltage threshold comes from KL25Z
USB. This means that Freedom board and USB must be plugged in. Burning voltage for
OTP is generated by an onboard boost IC that is also powered by FRDM-KL25Z.
For manual mode, use SW6 to allow connection to 5.0 V power supply, and SW7 to
connect to 8.0 V power supply; when VDBG65TH is reached a blue LED (D19) turns On.
Table 14 shows the possible output voltage level to apply to VDebug pin depending on
SW6 and SW7 positions.
SW6
SW7
VDebug (J13-2) voltage level
OFF
OFF
0 V
OFF
ON
7.8 V
ON
OFF
4.5 V
ON
ON
7.8 V
Table 14. SW6 and SW7 VDebug output configuration
When automatic mode is selected on connector J13 and KL25Z is plugged in and used,
5.0 V and 8.0 V thresholds can be controlled on the NXP GUI by KL25Z signals. It is also
possible to control VBAT by a MCU signal to generate automated sequences for program
and emulations; these signals are:
VBAT_Ctrl: Open or close VBAT power supply
MCU_DBG5V: 5.0 V on VDEBUG pin
MCU_DBG8V: 8.0 V on VDEBUG pin
Debug mode entry
To enter debug mode, follow the sequence:
1. VBAT Off (SW1)
2. VDebug (J13) > VDBG4TH
3. VBAT On (SW1)
4. At this step Debug mode is enabled and you can emulate an OTP configuration or
access the SPI register map. You can read FS_STATES register to verify you are in
Debug mode.
UM11503
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2021. All rights reserved.
User manual
Rev. 1 — 29 January 2021
13 / 60



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com