| Os motores de busca de Datasheet de Componentes eletrônicos |
|
52B Folha de dados(PDF) 4 Page - MKS Instruments. |
|
|
|||||||||||||||||||||||||||||
52B Folha de dados(HTML) 4 Page - MKS Instruments. |
|
4 / 4 page ![]() Ordering Information Dimensional Drawing: Flow Through- Note: Unless otherwise specified, dimensions are nominal values in inches (mm referenced). 11T A CA 1 MKS Instruments, Inc. Global Headquarters 2 Tech Drive, Suite 201 Andover, MA 01810 Tel: 978.645.5500 Tel: 800.227.8766 (in U.S.A.) Web: www.mksinst.com 41B_52B - 1/18 © 2009-2018 MKS Instruments, Inc. All rights reserved. MKS products provided subject to the US Export Regulations. Diversion or transfer contrary to US law is prohibited. Specifications are subject to change without notice. mksinst™ is a trademark and Baratron® is a registered trademark of MKS Instruments, Inc., Andover, MA. Inconel® is a registered trademark of Inco Alloys International, Huntington, WV. Swagelok® and VCR® are registered trademarks of Swagelok Marketing Co., Solon, OH. 41B only 41B/42B only 41B/51B only 41B/51B only A 005 41B Ordering Code Example: 41B11TCA1AA005 41B, 42B, 51B, 52B Code Configuration Unheated Vacuum/Pressure Switch Single-ended gauge 41B Flow-through gauge 42B Single-ended absolute 51B Flow-through absolute 52B Full Scale Ranges Available (Contact Applications Engineering for other engineering units) 10 Torr 11T 30 Torr 31T 100 Torr 12T 500 Torr 52T 1000 Torr 13T 20 psi 21P 50 psi 51P 100 psi 12P 250 psi RDP 500 psi 52P For Reverse Calibration only1 (trip point below atmospheric pressure): 10 Torr 11D 30 Torr 31D 100 Torr 12D 500 Torr 52D 1000 Torr 13D 20 psi 21C 50 psi 51C 100 psi 12C 250 psi RDC 500 psi 52C Fittings NW 16 KF GA 1/8 NPT male FE 1/4 NPT male FB 4 VCR fixed male CA 4 VCR female CD 4 VCR fixed male 42B/52B only CH Input Voltage 10-20 VDC 1 20-30 VDC 2 Relay Mode Energizes with pressure above the set point A Energizes with pressure below the set point B Connector 9-pin Type “D” male A Flying leads - 2 ft. shielded cable F Trip Point2 Three digit value (in same units as F.S. ranges) XXX (For reverse calibration, the trip point is given as value below atmosphere.) 1 For a trip point of 000 (atmospheric pressure), use a reverse calibration Full Scale range code. 2 For the absolute model, the trip point is the actual pressure at which the relay should trip. For the atmosphere model, the trip point is the pressure above or below atmospheric pressure at which the relay should trip. MKS Instruments, Inc. Pressure & Vacuum Measurement Solutions Six Shattuck Road Andover, MA 01810 Tel: 978.975.2350 |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |