  BNC75-R-A-CF Datasheet HTML 1Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 2Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 3Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 4Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 5Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 6Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 7Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 8Page - DDK Ltd. BNC75-R-A-CF Datasheet HTML 9Page - DDK Ltd.  
Zoom Inzoom in Zoom Outzoom out
 6 / 9 page
background image
Unit:mm
http://www.ddknet.co.jp
BNC75 Series
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
 Moreover, the characteristic and the specification of the published product are the reference values.
 Please confirm the content with the latest delivery specifications when you use the product.
6
Boot
Ferule
Sleeve
Contact
Body
L
Boot
Cable
Sheath
Outer Conductor
15
Sleeve
Ferule
Pull out the edge
Stripper(P/N:89134)
Insulator
Cut off the outer conductor
Cut the insulator and center conductor
along this side
Center Conductor
4.8 3.4
Insulator
Center Conductor
Crimping Hole
Crimp Tool
Crimped
Contact
Crimp Tool
Crimp Position
Body
Push the crimp tool into
the root of body.
Boot
○Assembly Instruction(2)
Boot
Ferule
Sleeve
Contact
Body
L
Boot
Cable
Sheath
Outer Conductor
15
Sleeve
Ferule
Pull out the edge
Stripper(P/N:89134)
Insulator
Cut off the outer conductor
Cut the insulator and center conductor
along this side
Center Conductor
4.8 3.4
Insulator
Center Conductor
Crimping Hole
Crimp Tool
Crimped
Contact
Crimp Tool
Crimp Position
Body
Push the crimp tool into
the root of body.
Boot
①
②
③
④
The cable length require for the double-ended cable
assembly.
L-12mm
① Insert the boot into the cable and cut the cable
as fig.1. Please be carefule to not damage the outer
conductor.
② Insert the ferule toward outer conductor.
Spread the outer conductor and press in the
sleeve with stripper (P/N:89134).
③ Cut the extra outer conductor and insulator
from the stripper along the surface as fig.3.
④ Push the edge of the stripper and rotate.
Separate the insulator toward the arrow.
 Cut the outer conductor along the surface of sleeve.
Parts Configulration



Html Pages

1 2 3 4 5 6 7 8 9


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com