| Os motores de busca de Datasheet de Componentes eletrônicos |
|
STUSB1600 Folha de dados(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STUSB1600 Folha de dados(HTML) 14 Page - STMicroelectronics |
|
14 / 69 page ![]() Features description STUSB1600 14/69 DocID028937 Rev 1 3.2 VBUS power path control 3.2.1 VBUS monitoring The VBUS monitoring block supervises (from the VBUS_SENSE pin) the VBUS voltage on the USB Type-C receptacle side. It is used to check that the VBUS is within a valid voltage range: • To establish a valid source-to-sink connection according to USB Type-C standard specifications. • To safely enable the VBUS power path through the VBUS_EN_SRC pin or VBUS_EN_SNK pin depending on the power role. It allows detection of unexpected VBUS voltage conditions such as undervoltage or overvoltage relative to the valid VBUS voltage range. When such conditions occur, the STUSB1600 reacts as follows: • At attachment, it prevents the source-to-sink connection and the VBUS power path assertion. • After attachment, it deactivates the source-to-sink connection and disables the VBUS power path. In source power role, the device goes into error recovery state. In Sink power role, the device goes into unattached state. The valid VBUS voltage range is defined from the VBUS nominal voltage by a high threshold voltage and a low threshold voltage whose nominal values are respectively VBUS+5% and VBUS-5%. The nominal threshold limits can be shifted by a fraction of VBUS from +1% to +15% for the high threshold voltage and from -1% to -15% for the low threshold voltage. This means the threshold limits can vary from VBUS+5% to VBUS+20% for the high limit and from VBUS-5% to VBUS-20% for the low limit. The threshold limits are preset by default in the NVM with different shift coefficients depending on whether the device operates in source power role or in sink power role (see Section 8.3: Electrical and timing characteristics). The threshold limits can be changed independently through NVM programming (see Section 6: Start-up configuration) and also by software during attachment through the I2C interface (see Section 5.1: Register description). 3.2.2 VBUS discharge The monitoring block also handles the internal VBUS discharge path connected to the VBUS_SENSE pin. The discharge path is activated at detachment, or when the device goes into the error recovery state whatever the power role (see Section 3.7: Hardware fault management). The VBUS discharge path is enabled by default in the NVM and can be disabled through NVM programming only (see Section 6: Start-up configuration). The discharge time duration is also preset by default in the NVM (see Section 8.3: Electrical and timing characteristics). The discharge time duration can be changed through NVM programming (see Section 6: Start-up configuration) and also by software through the I2C interface (see Section 5.1: Register description). |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |