17 / 29 page ![]() Functional Description (Continued) By default Temperature Register data is represented by a 9-bit two’s complement digital word with the LSB having a resolution of 0.5˚C: Temperature Digital Output Binary Hex +125˚C 0 1111 1010 0 FAh +25˚C 0 0011 0010 0 32h +1.5˚C 0 0000 0011 0 03h +0˚C 0 0000 0000 0 00h −0.5˚C 1 1111 1111 1 FFh −25˚C 1 1100 1110 1 CEh −55˚C 1 1001 0010 1 92h Temperature Register data can also be represented by a 12-bit two’s complement digital word with a LSB of 0.0625˚C: Temperature Digital Output Binary Hex +125˚C 0111 1100 0000 7 D0h +25˚C 0001 1001 0000 1 90h +1.0˚C 0000 0001 0000 0 10h +0.0625˚C 0000 0000 0001 0 01h 0˚C 0000 0000 0000 00h −0.0625˚C 1111 1111 1111 F FFh −1.0˚C 1111 1111 0000 F F0h −25˚C 1110 0111 0000 E 70h −55˚C 1100 1001 0000 C 90h The 8 MSBs of the Temperature reading can be found at Value RAM address 28 h. The remainder of the Temperature reading can be found in the OS Configuration/Temperature Resolution Register bits 7-4. In 9-bit format bit 7 is the only valid bit. 7.2 Temperature Interrupts There are four Value RAM WATCHDOG limits for the Tem- perature reading that affect the INT and OS outputs of the LM80. They are: Hot Temperature Limit, Hot Temperature Hysteresis Limit, OS Limit, OS Hysteresis Limit. There are three interrupt modes of operation: “One-Time Interrupt” mode, “Default Interrupt” mode, and “Comparator Mode”. The OS output of the LM80 can be programmed for “One-Time Interrupt” mode and “Comparator” mode. INT can be programmed for “Default Interrupt” mode and “One-Time” Interrupt. “Default Interrupt mode” operates in the following way: Ex- ceeding T hot causes an Interrupt that will remain active in- definitely until reset by reading Interrupt Status Register 1 or cleared by the INT_Clear bit in the Configuration register. Once an Interrupt event has occurred by crossing T hot, then reset, an Interrupt will occur again once the next temperature conversion has completed. The interrupts will continue to oc- cur in this manner until the temperature goes below T hot hyst, at which time the Interrupt output will automatically clear. “One-Time Interrupt” mode operates in the following way: Exceeding T hot causes an Interrupt that will remain active in- definitely until reset by reading Interrupt Status Register 1 or cleared by the INT_Clear bit in the Configuration register. Once an Interrupt event has occurred by crossing T hot, then reset, an Interrupt will not occur again until the temperature goes below T hot hyst. “Comparator” mode operates in the following way: Ex- ceeding T os causes the OS output to go Low (default). OS will remain Low until the temperature goes below T os. Once the temperature goes below T os, OS will go High. www.national.com 17 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |