1 / 4 page ![]() www.e-t-a.de Solid State Remote Power Controller E-1072-100 1646 1 5 E-1072-100 Description The E-T-A Solid State Remote Power Controller E-1072-100 is a double pole electronic switching amplifier suitable for resistive and inductive loads (solenoids, magnetic brakes etc.) as well as for lamp loads and capacitive loads. The double pole electronic switching output eliminates inadvertent start-up or dangerous machine movements as may arise upon a ground fault in systems with ungrounded power supply (‘IT systems’) (see Machinery Directive EN 60204 part 1, para. 9.4.3.1). Typical applications l Two pole actuator switching for machinery and plants. l Monitoring of the electrical functionability of these loads. l In-rush current limitation of lamp and capacitive loads. l Protection of load circuit cables. l ON and fault indication (by LEDs or RED trip button) and signalling (via potential-free auxiliary contacts). l Two pole physical isolation upon overload or when tripped manually. Features l PLC controllable electronic switching amplifier (max. 3 A) with additional protective and control functions for DC 24 V loads (e.g. solenoids, magnetic brakes, electromagnetic clutches, monitoring and indicator lamps). l Overload and short-circuit proof double pole switching output with in-rush current and short-circuit limitation. l Electronic disconnection upon - an overload in the load circuit, - short-circuit in the load (load+/load-, load+/-US, and load-/+US), followed by 2-pole isolation of the load circuit (via relay contacts). l Control input “In/Ctrl” with control current indication (YELLOW LED). l “O.K.” and availability indication (GREEN LED). l Short-circuit and overload indication (fault indication F and RED LED). l “Err1” group fault signalisation – all faults will be signalled: - wire breakage in the load circuit - earth fault at switching output - internal faults - overload or short circuit in the load circuit l “Err2” fault signalisation: - only overload or short circuit in the load circuit - reset required l Integral protection against reverse polarity and overvoltage for the control and load circuit. Ordering information Type No. E-1072 Solid State Remote Power Controller SSRPC 100 (trips only with overload or short circuit) Voltage rating of load DC 24 V Current rating 3 A E-1072 - 100 - DC 24 V - 3 A Technical data (Tambient = 25 °C, US = DC 24 V) Voltage rating UN DC 24 V Operating voltage US DC 19.2...36 V Current rating IN max. 3 A Current consumption I0 typically 24 mA (UContr = “0”) Power loss Pmax (IN=3 A) typically 3.5 W Residual ripple for all voltages max. 5 % (3 phase bridge) Reverse polarity protection US integral -> fault release, LEDs not lighting Caution: Ensure free travel of actuator button. Insulation voltage AC 500 V (control circuit, load circuit, fault indication “Err1” and “Err2”) Load Circuit Load output two pole switching output (minus and plus (term. 31-term. 32) switching), MOS transistors Max. load data DC 24 V/3 A (no derating over the entire temperature range!) Min. load data DC 24 V / 50 mA (wire break threshold 30 mA) Voltage drop at IN typically 0.9 V (Ri typically 300 mΩ) Switch times (ton / toff) typically 2 ms (resistive load) Overload disconnection approx 1.15 x IN (typically 3.45 A) Trip time (Iload= 2 x IN) typically 400 ms Short-circuit current IK typically 12 A current limitation Trip time (upon IK) typically 50 ms, 2-pole isolation of load circuit after approx. 200 ms –> RED LED indicates, fault indication F “Err1” and “Err2” Wire break monitoring with the load switched on or off; RED LED “Error” lighted, group fault signalisation “Err1” (UContr= “0”) wire break threshold Rload> 10 kΩ (UContr= “1”) minimum current Iload < 30 mA Supervision of load circuit with the load switched on, the load current is monitored via the two switching outputs GREEN LED indicates (OK signal), Iload > 30 mA Leakage current (UContr = “0”) typically 1 mA Free-wheeling circuitry integral Load current measurement no isolation of load circuit required as a (term. 33: +shunt/ 0.1 Ω/± 1 % measuring shunt is integral with term. 34: -shunt) the device. Measurement by voltmeter terminal 33 - terminal 34 (100 mV = 1 A) Isolation of load circuit 2-pole by relay contacts - by manual release of RED button - approx. 200 ms after electronic tripping due to overload or short circuit (“OFF”) |
Nº de peça semelhante - E-1072-100 |
|
Descrição semelhante - E-1072-100 |
|
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |