11 / 16 page ![]() INTEGRATED CIRCUITS DIVISION CPC7691 R01 www.ixysic.com 11 Under all start-up situations the CPC7691 will condition the internal switch control logic for the All-Off state thereby ensuring all of the switches will remain off during power-up. When VDD requirements have been satisfied the LCAS will complete it’s start-up procedure in one of three conditions. For start-up scenario 1, the CPC7691 will transition from the All-Off state to the state defined by the INRINGING input when VDD is valid. For start-up scenarios 2, 3, 5, and 6, the CPC7691 will power up in the All-Off state and remain there until the LATCH pin is pulled low. This allows for an indefinite All-Off state for boards inserted into a powered system but are not configured for service or boards that need to wait for other devices to be configured first. Scenario 4 will start up with all switches in the All-Off state, but upon the acceptance of a valid VDD the LCAS will revert to either the Talk state or the Ringing state, and thereafter may randomly change states based on input pin leakage currents and loading. This start-up condition should never be utilized as the LCAS state after power-up can not be predicted. For the start-up scenario when TSD = 0 the CPC7691 will condition the internal control logic for the All-Off state as it does when TSD 0. Start-up behavior with an initial TSD = 0 is dependent on when TSD is released with respect to the status of the Under Voltage Lock Out circuitry. Releasing TSD (which allows the internal pull-up to raise the input from a logic level low to a logic level high before, or concurrent with, the Under Voltage Lock Out deactivation) has no effect on the start-up behavior, and the start-up scenarios previously described are applicable. With TSD held low beyond the deactivation of the internal Under Voltage Lock Out control, the device will remain in the All-Off state regardless of the levels on the INRINGING or LATCH inputs. However, it is important to note that the LATCH is fully functional once the Under Voltage Lock Out deactivates. This allows the LATCH to be preconfigured to the state desired with the release of TSD. 2.6 VBAT Pin Although battery power is not used for switch control, it is required to direct negative potential faults away from the SLIC. Because the CPC7691 requires VBAT to protect the SLIC from negative potential faults, the CPC7691 will deactivate and enter the All-Off state whenever VBAT is unavailable. 2.6.1 Protection In the presence of a negative potential fault the CPC7691BA will draw current from VBAT to supply trigger current for the internal integrated protection circuitry SCR. This integrated SCR is designed to activate whenever the voltage at TBAT or RBAT drops 2V to 4V below the applied voltage on the VBAT pin. Because the battery supply at this pin is required to source trigger current during negative over-voltage fault conditions at tip and ring, it is important that the net supplying this current be a low impedance path for high speed transients such as lightning. This will permit trigger currents to flow enabling the SCR to activate, and thereby prevent a fault induced negative over-voltage event at the TBAT or RBAT nodes. Although the CPC7691BB does not have the SCR for negative potential fault protection, it utilizes a power switching diode from each of the TBAT and RBAT nodes to VBAT, which forward conduct in the presence of potentials at these nodes more negative than VBAT. Proper protection requires VBAT to supply sufficient current to counter the transient fault currents restricted by the current limit functions of the break switches. 2.6.2 Battery Voltage Monitor The CPC7691 also uses the VBAT pin to monitor the battery voltage. If system battery voltage is lost, the CPC7691 immediately enters the All-Off state, and remains in this state until the battery voltage is restored. An internal detector monitoring the system battery voltage forces the All-Off state anytime the battery voltage goes more positive than –10V. The All-Off state is maintained until the battery voltage goes more negative than –15 V. This battery monitor feature draws a small current from VBAT (typically <1 A) and will add slightly to the device’s overall power dissipation. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |