| Os motores de busca de Datasheet de Componentes eletrônicos |
|
IQS550 Folha de dados(PDF) 21 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
IQS550 Folha de dados(HTML) 21 Page - List of Unclassifed Manufacturers |
|
21 / 80 page ![]() IQ Switch ® ProxSense ® Series Copyright © Azoteq (Pty) Ltd IQS5xx-B000 Trackpad Datasheet Page 21 of 80 All Rights Reserved. Revision 1.1 October 2015 Table 5.1 Mapping Example Column number (mapped Rx) Row number (mapped Tx) 0 (Rx3) 1 (Rx0) 2 (Rx8) 3 (Rx1) 4 (Rx2) 0 (Tx0) 5x5 Trackpad 1 (Tx1) 2 (Tx13) 3 (Tx12) 4 (Tx11) 5.1.4 Rx to Tx switch (IQS525 only) The IQS525 has 2 Tx electrodes, and 8 Rx electrodes. However any of the Rxs can be configured to take on Tx functionality. This is configured in the IQS525 RxToTx register. The corresponding Rx or Tx number is then used in the mapping registers to configure the order of the electrodes. 5.2 Trackpad Outputs The channel count variation (deltas) and touch status outputs are used to calculate finger location data. 5.2.1 Number of Fingers This gives an indication of the number of active finger inputs on the trackpad (Number of fingers). 5.2.2 Relative XY If there is only one finger active, a Relative X and Relative Y value is available. This is a sig ned 2‟s complement 16-bit value. It is a delta of the change in X and Y, in the scale of the selected output resolution. Note: Gestures also use these registers to indicate swipe, scroll and zoom parameters. 5.2.3 Absolute XY For all the multi-touch inputs, the absolute finger position (Absolute X/Y), in the selected resolution (Resolution X/Y) of the trackpad, is available. 5.2.4 Touch Strength This value (Touch strength) indicates the strength of the touch by giving a sum of all the deltas associated with the finger, and therefore varies according to the sensitivity setup of the sensors. 5.2.5 Area The number of channels associated with a finger is provided here. This area is usually equal to or smaller than the number of touch channels under the finger. 5.2.6 Tracking / Identification The fingers are tracked from one cycle to the next, and the same finger will be located in the same position in the memory map. The memory location thus identifies the finger. 5.3 Max Number of Multi-touches The maximum number of allowed multi- touches is configurable (Max multi-touches) up to 5 points. If more than the selected value is sensed, a flag is set (TOO_MANY_FINGERS) and the XY data is cleared. 5.4 XY Resolution The output resolution for the X and Y coordinates are configurable (X/Y Resolution). The on-chip algorithms use 256 points between each row and column. The resolution is defined as the total X and total Y output range across the complete trackpad. 5.5 Palm Rejection A maximum finger size/area (Palm reject threshold) can be set up to allow for palm rejection or similar input suppression. This feature can be enabled or disabled (PALM_REJECT), and when a palm reject condition is sensed, a status flag will indicate this result (PALM_DETECT). All XY outputs are also suppressed during palm detection. Palm reject is latched on for the timeout period (Palm reject timeout) to prevent erratic behaviour before and after the palm is seen. This timeout sets in increments of 32ms. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |