| Os motores de busca de Datasheet de Componentes eletrônicos |
|
E5AZ-R3T Folha de dados(PDF) 54 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5AZ-R3T Folha de dados(HTML) 54 Page - Omron Electronics LLC |
|
54 / 64 page ![]() E5EZ-PRR 54 Meaning Internal memory operation is in error. Action First, turn the power OFF then back ON again. If the display remains the same, the Controller must be repaired. If the display is restored, then the probable cause is electrical noise affecting the control system. Check for electrical noise. Operation at Error Control output and alarm output turn OFF. Meaning Valve opening has exceeded its regular range of −10% to 110%. Action Check to see if there have been any wiring errors, burnouts, or short-circuits in the potentiometer. If there are no problems with the wiring, you can restart the power supply. If the display remains the same, the Controller must be replaced. If the display is re- stored, then the probable cause is interference which should be avoided. Operation at Error Control output will output MV based on the “MV during error” setting position. Alarm output will operate as normal. Meaning Motor calibration did not completely finish. Action After confirming the potentiometer and the wiring of the motor driving valve, per- form motor calibration again. Operation at Error Control output and alarm output set to OFF. Memory Error e111 9999 (999.9) −1999 ( −199.9) −1999 ( −199.9) 9999 (999.9) Platinum resistance thermometer input (Except for models with a setting range of −199.9 to 500.0°C) Thermocouple input (Except for models with a setting range of −199.9 to 400.0°C) ES1B Control range s.err display Numeric display s.err display Input indication range Analog (current, voltage) Input • When display range < control range Control range s.err display [[[[ display Numeric display Input indication range ]]]] display s.err display Display range Platinum resistance thermometer input (Except for models with a setting range of −199.9. to 500.0°C) Thermocouple input (Except for models with a setting range of −199.9 to 400.0°C) Control range s.err display [[[[ display Numeric display Input indication range Input indication range s.err display Analog Input • When display range > control range Control range s.err display Numeric display s.err display Display range ---- Potentiometer Input Error err Motor Calibration Error |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |