24 / 38 page ![]() Feedback loop calculation guidelines AN4116 24/38 Doc ID 023220 Rev 1 7 Feedback loop calculation guidelines 7.1 Transfer function The set PWM modulator + power stage is indicated with G1(f), while C(f) is the “controller”, i.e. the network which is in charge to ensure the stability of the system. The mathematical expression of the power plant G1(f) is the following: Equation 2 where fp is the pole due to the output load and fz the zero due to the ESR of the output capacitor: Equation 3 Equation 4 Figure 38. Control loop block diagram AM11582v1 ) fp j (1 ) , ( ) fz (1 V ) p 2 j (1 ) , ( ) z 2 (1 V = I V (f) G OUT OUT pk OUT 1 f Vdc fsw Ipkp f j f Vdc fsw Ipkp f j ⋅ + ⋅ ⋅ + ⋅ = ⋅ ⋅ ⋅ + ⋅ ⋅ ⋅ ⋅ + ⋅ Δ Δ = π π 2ESR) + ·(R C 1 fp OUT OUT ⋅ = π ·ESR C 2 1 fz OUT ⋅ ⋅ = π |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|