AN2690 Folha de dados(HTML) 21 Page - STMicroelectronics |
|
21 / 31 page ![]() AN2690 Conducted emission pre-compliance test 21/31 5 Conducted emission pre-compliance test Figure 23 and 24 show the peak measurement of the conducted noise at full load and nominal mains voltages. The limits shown on the diagrams are the EN55022 Class-B ones, which is the most popular rule (or standard) for domestic equipment and it has more severe limits compared to the Class-A, dedicated to IT equipment. As shown in the diagrams, under all test conditions the measures are within the limits. Figure 23. CE peak measure at 115 Vac and full load Figure 24. CE peak measure at 230 Vac and full load |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|