20 / 24 page ![]() Evaluations of circuit with PNP and current limitation AN3399 20/24 Doc ID 018824 Rev 2 2.2.4 VS cranking measurement Screenshots of behavior in case of VS cranking pulse for various pulse widths are at the next figures. In case VS reaches level for POR the V2 is switched off and as a consequence V3 is switched off as well. Figure 27. VS cranking (1 ms pulse) Figure 27 is a screenshot of VS cranking pulse 1 ms width. The VS under-voltage flag was set in status register, but V2 remains ON. Figure 28. VS cranking (pulse 2 ms) On Figure 28 VS reaches the level of power on reset. V2 was switched OFF and cold start diagnosis bit was signalized in status registers. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|