| Os motores de busca de Datasheet de Componentes eletrônicos |
|
LCC110STR Folha de dados(PDF) 3 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LCC110STR Folha de dados(HTML) 3 Page - Clare, Inc. |
|
3 / 8 page ![]() LCC110 www.clare.com Rev. 4 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 3 LCC110 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) LCC110 - FormA Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC, IF=8mADC) 35 30 25 20 15 10 5 0 19.5 21.5 23.5 25.5 20.5 22.5 24.5 On-Resistance ( Ω) LCC110 - FormA Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 400 440 480 520 420 460 500 Blocking Voltage (V) LCC110 - FormB Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 30 25 20 15 10 5 0 365 385 405 425 375 395 415 Blocking Voltage (V) LCC110 - FormB Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC, IF=8mADC) 30 25 20 15 10 5 0 25.5 27.5 29.5 31.5 26.5 28.5 30.5 On-Resistance ( Ω) LCC110 - FormA Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 1.2 2.8 4.4 2.0 3.6 5.2 LED Current (mA) 25 20 15 10 5 0 LCC110 - FormB Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 30 25 20 15 10 5 0 1.2 2.0 3.6 5.2 2.8 LED Current (mA) 4.4 LCC110 - FormA Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 LED Current (mA) 1.2 2.0 3.6 5.2 2.8 4.4 LCC110 - FormB Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 LED Current (mA) 1.2 2.0 3.6 4.4 5.2 2.8 LCC110 - FormA Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 8mADC) 1.2 2.8 5.2 2.0 3.6 Turn-On (ms) 25 20 15 10 5 0 4.4 LCC110 - FormB Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 8mADC) 0.03 0.07 0.11 0.05 0.09 0.13 Turn-On (ms) 30 25 20 15 10 5 0 LCC110 - FormA Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 8mADC) 0.14 0.05 0.32 0.50 0.41 0.23 Turn-Off (ms) 25 20 15 10 5 0 |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |