14 / 34 page ![]() www.austriamicrosystems.com Revision 17920-001-10a 13 - 33 AS8220A Objective Data Sheet - Detailed Description NORMAL mode In this mode the transceiver is able to send and receive data signals on the bus. TxEN and BGE control the state of the transmitter. RxD reflects the bus data and reflect the bus state. In this mode, the transmitter state can be selected as shown in the Table 5. In case the over-temperature flag is set the transmitter is disabled. The bus wires are terminated to VCC/2 via receiver input resistances. Table 5. Transmitter State BGE TxEN TxD Transmitter state Bus State If the differential bus voltage is higher than VBUSActivehigh or lower than VBUSActivelow for a time longer than tBUSAc- tivityDetection, then activity is detected on the bus (Bus = active), RxD is released. If, after the activity detection, the differential bus voltage is higher than VData1, RxD is high. If, after the activity detection, the differential bus voltage is lover than VData0, RxD is low. If the absolute differential bus voltage is lower than VBUSActivehigh and higher than VBUSActivelow for a time longer than tBUSIdleDetection, then idle is detected on the bus (Bus=idle), RxD is switched to logical “high” STANDBY mode In this mode the transceiver is not able to send and receive data signals from the bus. The power consumption is significantly reduced respect the NORMAL mode. The bus wires are terminated to GND (bus state: Idle_LP). Non Operating Mode The AS8220A provides the following non operating mode: Power Off In this mode the transceiver is not able to operate. RxD is set to high and ERRN is set to low. The bus wires are not connected to GND (bus state: Idle_HZ). Undervoltage Events Undervoltage VIO When VIO voltage falls below VIOTHL for a time longer than tUV_DETECT then the undervoltage VIO flag is set and it is reset when VIO exceeds the voltage threshold VIOTHH for a time longer than tUV_REC. The flag can be set or reset in all the operation modes. The flag is reset at power off. Undervoltage VCC When VCC voltage falls below VCCTHL for a time longer than tUV_DETECT then the undervoltage VCC flag is set and it is reset when VCC exceeds the voltage threshold VCCTHH for a time longer than tUV_REC. The flag can be set or reset in all the operation modes. The flag is reset at power off. H L H Enabled Data1 (BP is driven high, BM is driven low) H L L Enabled Data0 (BP is driven low, BM is driven High) X H X Disabled Idle (BP and BM are not driven) L X X Disabled Idle (BP and BM are not driven) |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |