| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ACT3492 Folha de dados(PDF) 15 Page - Aeroflex Circuit Technology |
|
|
|||||||||||||||||||||||||||||
ACT3492 Folha de dados(HTML) 15 Page - Aeroflex Circuit Technology |
|
15 / 49 page ![]() Aeroflex Circuit Technology SCD3492 REV B 6/26/01 Plainview NY (516) 694-6700 15 PASMON INPUT F8 Passive Monitor - When functioning as a Bus Controller this line acts as a passive monitor select. The active going edge of this line will cause the REQBUS lines to be latched and that bus, now selected will be monitored so long as PASMON remains low. All traffic on the bus will be handed, after validation, to the subsystem via STATSTB for status and commands words, and RMDSTB for data words. BCOPSTB INPUT F7 Bus Controller Operation Strobe - When functioning as a Bus Controller a low going pulse on this line will initiate the selected bus controller operation on the requested bus, using BCOPA&B and REQBUSA&B. BCOPA INPUT B10 Bus Control Operation A - Least significant bit of the bus controller operation select lines. BCOPB INPUT C10 Bus Control Operation B - Most significant bit of the bus controller operation select lines. REQBUS A BIDIR E5 Request Bus A - This line, when in RT mode, is the least significant bit of the bus request lines which specify the origin of the command, i.e. they are sources. When in BC mode these lines are sinks and specify which bus is to be used for the next command. REQBUS B BIDIR H6 Request Bus B - Most significant bit of the bus request lines. (See above for description.) RT/BC INPUT B4 Remote Terminal/Bus Control - This line when high causes the ASIC to function as a remote terminal. When low the ASIC functions as a bus controller or passive monitor. DBCACC INPUT B3 Dynamic Bus Control Accept - This line should be permanently tied low if a subsystem is able to accept control of the bus if offered. LTFAIL OUTPUT E2 Loop Test Fail - This line goes low if any error in the transmitted waveform is detected or if any parity error in the hardwired RT address is detected. ERROR OUTPUT F2 Error - This line latches low if a Manchester or parity error is detected. It is reset by the next CMSYNC (RT mode) and also by RTO in the BC mode. RTO OUTPUT F3 Reply Time Out - This signal will pulse low whenever the reply time for a transmitting terminal has been exceeded. This line is intended for the bus controller use. TXTO OUTPUT C3 Transmitter Time Out - This line latches low if the transmitter time out limits are exceeded. PARER OUTPUT D3 Parity Error - This line will pulse low if a parity error is detected by the decoder. Pin Description (Cont.) Signal Direction Pin Signal Description |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |