15 / 16 page ![]() AD621 REV. B –15– GROUNDING Since the AD621 output voltage is developed with respect to the potential on the reference terminal, it can solve many ground- ing problems by simply tying the REF pin to the appropriate “local ground.” In order to isolate low level analog signals from a noisy digital environment, many data-acquisition components have separate analog and digital ground pins (Figure 15). It would be conve- nient to use a single ground line; however, current through ground wires and PC runs of the circuit card can cause hundreds of millivolts of error. Therefore, separate ground returns should be provided to minimize the current flow from the sensitive points to the system ground. These ground returns must be tied together at some point, usually best at the ADC package as shown. DIGITAL P.S. +5V C ANALOG P.S. +15V C –15V AD574A + AD621 AD585 S/H ADC 5 9 11 15 6 2 4 7 1 11 7 6 4 0.1 F 1 F 3 DIGITAL DATA OUTPUT 0.1 F 1 F1 F Figure 15. Basic Grounding Practice GROUND RETURNS FOR INPUT BIAS CURRENTS Input bias currents are those currents necessary to bias the input transistors of an amplifier. There must be a direct return path for these currents; therefore when amplifying “floating” input sources such as transformers, or ac-coupled sources, there must be a dc path from each input to ground as shown in Figures 16a through 16c. Refer to the Instrumentation Amplifier Application Guide (free from Analog Devices) for more information regard- ing in amp applications. +VS AD621 LOAD –VS REFERENCE TO POWER SUPPLY GROUND +INPUT –INPUT VOUT Figure 16a. Ground Returns for Bias Currents when Using Transformer Input Coupling +VS AD621 LOAD –VS REFERENCE TO POWER SUPPLY GROUND +INPUT –INPUT VOUT Figure 16b. Ground Returns for Bias Currents when Using a Thermocouple Input 100k 100k –INPUT AD621 +INPUT +VS –VS VOUT LOAD REFERENCE TO POWER SUPPLY GROUND Figure 16c. Ground Returns for Bias Currents when Using AC Input Coupling |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |