| Os motores de busca de Datasheet de Componentes eletrônicos |
|
MAS6512 Folha de dados(PDF) 10 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6512 Folha de dados(HTML) 10 Page - Micro Analog systems |
|
10 / 12 page ![]() DA6512.000 11 July, 2012 10 (26) MEASUREMENT CONTROL REGISTER (E2/62HEX) This register is used to configure and initiate a measurement. See table 3 below. A new conversion is started simply by writing 8-bit configuration data to the measurement control register (E2/62HEX). Table 3. Measurement control register (E2/62HEX) description Bit Number Bit Name Description Value Function 7-5 OSRS Over Sampling Ratio (OSR) Selection 000 001 010 011 100 OSR = 256 OSR = 512 OSR = 1024 OSR = 2048 OSR = 4096 4 REGEN Regulator Enable 0 1 Voltage regulator disabled Voltage regulator enabled 3 SCO Start Conversion 0 1 No conversion Start conversion 2 XETS Sensor Selection 0 1 External capacitive sensor Internal temperature sensor 1 - Not used - - 0 XRC Front end function selector 0 1 Ratio converter Difference converter The OSRS over sampling ratio selection bits choose between five different OSR values. High OSR value corresponds to high resolution but also longer conversion time. See Electrical characteristics for further details. The REGEN bit enables/disables the internal voltage regulator. When enabled the regulator is turned on during conversions and automatically turned off after each conversion to save power. During temperature measurements the regulator is always enabled regardless of the REGEN bit setting. Note that if Test register FOSC=1 and if REGEN=1 the regulator is forced on all the time independently of measurements. The SCO Start conversion bit needs to be set 1 for every new measurement. It is automatically reset to 0 after each measurement. The XETS Sensor selection bit controls the front- end multiplexer and connects either the external capacitive sensor (XETS=0) or the internal temperature sensor (XETS=1) to the ∆Σ-converter. The XRC bit selects between two external capacitive sensor measurement modes. It does not have any effect on temperature measurement. In Ratio converter mode the measured value will be proportional to capacitance ratio (CS-CR)/CS. In Difference converter mode the measurement will be proportional to capacitance difference (CS-CR). |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |