A
A
DS-EMOD-3 Oct ’07
©2007 RF Solutions Ltd, www.rfsolutions.co.uk
Page 2
Tel 01273 898000 Fax 01273 480661
EMOD
Waterproof Radio Remote Controls
Series
RLY 2
RLY 1
RLY 4
RLY 3
Antenna
(Black)
Fixing Hole
4mm DIA (R204 only)
Power Connections
5mm Spade terminals
NO NC
COM
0V (GND) Green
+12V Red
RLY
Supply
L
N GND
Load
COM
N/O
Application Circuit
N/C
Receiver Unit
Connections
The receiver can be powered from either 12Vdc as follows:
Red Wire:
Connect to 12Vdc for use with 12Vdc Supply only
Green Wire:
Connect to 0V (GND)
Black Wire:
Antenna. Do not cut this!. If possible position so that it protrudes in a vertical direction.
Data Outputs
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and
Normally Closed (NC).
Please Note: The relay contacts are for functional use only and must not be used for isolation purposes.
Technical Specifications
Dimensions
204 Transmitter:
96 x 47 x 23mm
120 Transmitter:
36 x 66 x 17 mm
EMOD Receiver:
82 x 62 x 34 mm
Storage Temperature: -10 to +70
o Celsius.
Operating Temperature: 0 to +55
o Celsius.
Electrical Characteristics
Min
Typical
Max
Units
Supply Voltage: 12V Supply
11
12
16
V
Supply Current :
Quiescent
All Relays Operating
9
300
mA
mA
Time from Tx Switch depressed to 210Rx output
100
mSecs
Time from Tx Switch release to Decoder output
200
mSecs
Relay Connections when
Transmitter NOT Operating
Relay Connections when
Transmitter OPERATING



Html Pages

1 2 3


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com