| Os motores de busca de Datasheet de Componentes eletrônicos |
|
TDF8599B Folha de dados(PDF) 21 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8599B Folha de dados(HTML) 21 Page - NXP Semiconductors |
|
21 / 54 page ![]() TDF8599B_1 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 01 — 29 July 2009 21 of 54 NXP Semiconductors TDF8599B I2C-bus controlled dual channel class-D power amplifier 8.6.2.3 AC load detection AC load detection is only available in I2C-bus mode and is controlled using bit IB3[D4]. The default setting for bit IB3[D4] = 0 disables AC load detection. When AC load detection is enabled (bit IB3[D4] = 1), the amplifier load current is measured and compared with a reference level. Pin CLIP is activated when this threshold is reached. Using this information, AC load detection can be performed using a predetermined input signal frequency and level. The frequency and signal level should be chosen so that the load current exceeds the programmed current threshold when the AC coupled load (tweeter) is present. 8.6.2.4 CLIP detection CLIP detection gives information for clip levels ≥ 0.2 %. Pin CLIP is used as the output for the clip detection circuitry on both channel 1 and channel 2. Setting either bit IB1[D5] or bit IB2[D5] to logic 0 defines which channel reports clip information on the CLIP pin. Fig 19. Recommended start-up sequence with DC load detection enabled 001aaj061 NO NO YES YES restart DC load start amplifier anyway I2C-bus TX IB1[D0] = 1 startup IB2[D2] = 1 enable DC load IB1[D1] = 1 disable channel 1 IB2[D1] = 1 disable channel 2 I2C-bus RX DB1[D4] = 1 channel 1 open load DB2[D4] = 1 channel 2 open load DB1[D6] = 1 DC load valid I2C-bus TX IB1[D0] = 1 startup IB2[D2] = 0 disable DC load IB1[D1] = 0 enable channel 1 IB2[D1] = 0 enable channel 2 I2C-bus TX IB1[D0] = 1 startup IB2[D2] = 0 disable DC load IB1[D1] = 1 disable channel 1 IB2[D1] = 1 disable channel 2 I2C-bus TX IB1[D0] = 1 startup IB2[D2] = 1 enable DC load IB1[D1] = 1 disable channel 1 IB2[D1] = 1 disable channel 2 ERROR HANDLING COUNT = 0 WAIT DC load COUNT = COUNT + 1 DB1[D6] = 1 DC load valid COUNT ≤ COUNTMAX |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |