Back Button TLC320AC02IPM Datasheet HTML 9Page - Texas Instruments TLC320AC02IPM Datasheet HTML 10Page - Texas Instruments TLC320AC02IPM Datasheet HTML 11Page - Texas Instruments TLC320AC02IPM Datasheet HTML 12Page - Texas Instruments TLC320AC02IPM Datasheet HTML 13Page - Texas Instruments TLC320AC02IPM Datasheet HTML 14Page - Texas Instruments TLC320AC02IPM Datasheet HTML 15Page - Texas Instruments TLC320AC02IPM Datasheet HTML 16Page - Texas Instruments TLC320AC02IPM Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 84 page
background image
1–6
1.4
Terminal Functions (Continued)
TERMINAL
I/O
DESCRIPTION
NAME
NO.†
NO.‡
I/O
DESCRIPTION
OUT+
3
43
O
Noninverting output of analog output power amplifier. OUT+ can drive transformer
hybrids or high-impedance loads directly in a differential connection or a
single-ended configuration with a buffered VMID.
OUT–
4
46
O
Inverting output of analog output power amplifier. OUT– is functionally identical
with and complementary to OUT+.
PWR DWN
2
42
I
Power-down input. When PWR DWN is taken low, the device is powered down
such that the existing internally programmed state is maintained. When PWR
DWN is brought high, full operation resumes.
RESET
8
57
I
Reset input that initializes the internal counters and control registers. RESET
initiates the serial data communications, initializes all of the registers to their
default values, and puts the device in a preprogrammed state. After a low-going
pulse on RESET, the device registers are initialized to provide a 16-kHz
data-conversion rate and 7.2-kHz filter bandwidth for a 10.368-MHz master clock
input signal.
SCLK
13
8
I/O
Shift clock. SCLK clocks the digital data into DIN and out of DOUT during the
frame-synchronization interval. When configured as an output (M/S high), SCLK
is generated internally by dividing the master clock signal frequency by four. When
configured as an input (M/S low), SCLK is generated externally and
synchronously to the master clock. This signal clocks the serial data into and out
of the device.
SUBS
21
24
I
Substrate connection. SUBS should be tied to ADC GND.
† Terminal numbers shown are for the FN package.
‡ Terminal numbers shown are for the PM package.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com