Back Button HD6417618A Datasheet HTML 362Page - Renesas Technology Corp HD6417618A Datasheet HTML 363Page - Renesas Technology Corp HD6417618A Datasheet HTML 364Page - Renesas Technology Corp HD6417618A Datasheet HTML 365Page - Renesas Technology Corp HD6417618A Datasheet HTML 366Page - Renesas Technology Corp HD6417618A Datasheet HTML 367Page - Renesas Technology Corp HD6417618A Datasheet HTML 368Page - Renesas Technology Corp HD6417618A Datasheet HTML 369Page - Renesas Technology Corp HD6417618A Datasheet HTML 370Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 366 / 646 page
background image
Section 14 Serial Communication Interface with FIFO (SCIF)
Rev. 6.00 Jun. 12, 2007 Page 334 of 610
REJ09B0131-0600
14.3.6
Serial Control Register (SCSCR)
SCSCR is a 16-bit register that operates the SCIF transmitter/receiver, enables/disables interrupt
requests, and selects the transmit/receive clock source. The CPU can always read and write to
SCSCR. SCSCR is initialized to H'0000 by a power-on reset.
Bit
Bit Name
Initial
value
R/W
Description
15 to 8
All 0
R
Reserved
These bits are always read as 0. The write value should
always be 0.
7
TIE
0
R/W
Transmit Interrupt Enable
Enables or disables the transmit-FIFO-data-empty
interrupt (TXI).
Serial transmit data in the transmit FIFO data register
(SCFTDR) is send to the transmit shift register
(SCTSR). Then, the TDFE flag in the serial status
register (SCFSR) is set to1 when the number of data in
SCFTDR becomes less than the number of
transmission triggers. At this time, a TXI is requested.
0: Transmit-FIFO-data-empty interrupt request (TXI) is
disabled*
1: Transmit-FIFO-data-empty interrupt request (TXI) is
enabled
Note: * The TXI interrupt request can be cleared by
writing a greater number of transmit data than
the specified transmission trigger number to
SCFTDR and by clearing the TDFE bit to 0
after reading 1 from the TDFE bit, or can be
cleared by clearing this bit to 0.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com